TID Effect Test of the ICS307GI-03LF Serially Programmable Clock Source for Space Applications

Cited 6 time in webofscience Cited 0 time in scopus
  • Hit : 444
  • Download : 11
DC FieldValueLanguage
dc.contributor.authorShin, Goo-Hwanko
dc.contributor.authorRyu, Kwang-Sunko
dc.contributor.authorMyung, Noh-Hoonko
dc.contributor.authorKim, Ee-Eulko
dc.date.accessioned2013-03-11T16:20:45Z-
dc.date.available2013-03-11T16:20:45Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2011-08-
dc.identifier.citationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.59, pp.670 - 673-
dc.identifier.issn0374-4884-
dc.identifier.urihttp://hdl.handle.net/10203/99584-
dc.description.abstractThe ICS307GI-03LF is a dynamic, serially programmable clock source that is flexible and takes up minimal board space and whose output frequencies are programmed via a serial interface port. The device can be programmed during operation, making it ideal for applications where many different frequencies are required. To apply it to space parts, we have performed a total ionizing dose (TID) test for the ICS307GI-03LF serially programmable clock source by using a low-level gamma irradiator with (60)Co gamma-ray sources at the ARTI (Advanced Radiation Technology Institute), which belongs to the KAERI (Korea Atomic Energy Research Institute). The irradiation with gamma-rays was carried out at doses from 0 krad to 100 krad to check the status of the device in terms of frequency and current. In this paper, we report on the TID test results for the ICS307GI-03LF clock source.-
dc.languageEnglish-
dc.publisherKOREAN PHYSICAL SOC-
dc.subjectMEMORY-
dc.titleTID Effect Test of the ICS307GI-03LF Serially Programmable Clock Source for Space Applications-
dc.typeArticle-
dc.identifier.wosid000294079700032-
dc.identifier.scopusid2-s2.0-79961232428-
dc.type.rimsART-
dc.citation.volume59-
dc.citation.beginningpage670-
dc.citation.endingpage673-
dc.citation.publicationnameJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.contributor.localauthorShin, Goo-Hwan-
dc.contributor.localauthorMyung, Noh-Hoon-
dc.contributor.nonIdAuthorKim, Ee-Eul-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorTotal ionizing dose-
dc.subject.keywordAuthorSpace radiation-
dc.subject.keywordAuthorSerially programmable clock source-
dc.subject.keywordAuthorFrequency-
dc.subject.keywordAuthorCurrent-
dc.subject.keywordPlusMEMORY-
Appears in Collection
RIMS Journal PapersEE-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 6 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0