Consideration of the leakage-current and the radiation-response characteristics of silicon PIN detectors with different N-type substrates and their application to a personal gamma-ray dosimeter

Cited 3 time in webofscience Cited 0 time in scopus
  • Hit : 505
  • Download : 179
DC FieldValueLanguage
dc.contributor.authorPark, Jong-Moonko
dc.contributor.authorPark, Kun-Sikko
dc.contributor.authorYoon, Yong-Sunko
dc.contributor.authorKoo, Jin-Gunko
dc.contributor.authorKim, Bo-Wooko
dc.contributor.authorChae, Hyun-Sicko
dc.contributor.authorNo, Kwang-Sooko
dc.contributor.authorYoon, Chang-Jooko
dc.date.accessioned2008-11-24T02:17:58Z-
dc.date.available2008-11-24T02:17:58Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2007-07-
dc.identifier.citationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.51, pp.10 - 17-
dc.identifier.issn0374-4884-
dc.identifier.urihttp://hdl.handle.net/10203/7900-
dc.description.abstractThe effects of resistivity and crystal orientation on the leakage-current and the radiation-response characteristics of silicon PIN detectors have been studied. A high-resistive substrate (> 8 k Omega.cm) shows a larger leakage current than a low-resistive one (< 4 k Omega.cm) at low reverse bias because of its wider depletion width, but the opposite result is seen at high reverse bias. We think that the thermionic field emission (TFE) current increases at high reverse bias for a low-resistive substrate. The detector with a (111)-oriented substrate exhibits leakage current chacteristics comparable to those of the (100)-oriented one when the resistivity of the substrate is 3.8 k Omega.cm. An X-ray beam irradiation test showed that the output current of the detector with the (Ill)-oriented substrate was 20 % higher than that of the (100) -orientated one and that the result was independent of the resistivity of the substrate. Based on the results, we fabricated a silicon PIN detector for a personal gamma ray dosimeter operated at 3 V with a substrate having a (111) orientation and a resistivity of 3.8 k Omega.cm, and we assembled it with read-out integrated circuit. Our detector was sensitive to Cs-137 natural gamma rays and showed a good linearity in the exposure rate.-
dc.languageEnglish-
dc.language.isoen_USen
dc.publisherKOREAN PHYSICAL SOC-
dc.subjectFABRICATION-
dc.subjectBREAKDOWN-
dc.titleConsideration of the leakage-current and the radiation-response characteristics of silicon PIN detectors with different N-type substrates and their application to a personal gamma-ray dosimeter-
dc.typeArticle-
dc.identifier.wosid000248062900003-
dc.identifier.scopusid2-s2.0-34547667015-
dc.type.rimsART-
dc.citation.volume51-
dc.citation.beginningpage10-
dc.citation.endingpage17-
dc.citation.publicationnameJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.contributor.localauthorNo, Kwang-Soo-
dc.contributor.nonIdAuthorPark, Jong-Moon-
dc.contributor.nonIdAuthorYoon, Yong-Sun-
dc.contributor.nonIdAuthorKoo, Jin-Gun-
dc.contributor.nonIdAuthorKim, Bo-Woo-
dc.contributor.nonIdAuthorChae, Hyun-Sic-
dc.contributor.nonIdAuthorYoon, Chang-Joo-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorleakage currents-
dc.subject.keywordAuthorsilicon PIN diodes-
dc.subject.keywordAuthorradiation detectors-
dc.subject.keywordPlusFABRICATION-
dc.subject.keywordPlusBREAKDOWN-
Appears in Collection
MS-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 3 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0