슬릿광 3차원 형상측정에서 측정분해능 최적화를 위한 시스템설계 및 카메라보정System Design and Camera Calibration of Slit Beam Projection for Maximum Measuring Accuracy

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 410
  • Download : 0
This paper presents an enhanced method of slit beam projection intended for the rapid measurement of 3-dimensional surface profiles of dies and molds. Special emphasis is given to optimizing the design of optical system so that the measuring accuracy can be maximized by adopting two-plane camera calibration together with sub-pixel image processing techniques. Finally, several measurement examples are discussed to demonstrate that an actual measuring accuracy of ± 0.2 mm can be achieved over the measuring range of 500 mm{\times}300mm{\times}200mm.$
Publisher
대한기계학회
Issue Date
1994-05
Language
Korean
Citation

대한기계학회논문집 A, v.18, no.5, pp.1182 - 1191

ISSN
1226-4873
URI
http://hdl.handle.net/10203/66907
Appears in Collection
ME-Journal Papers(저널논문)