A conformable microneedle sensor with photopatternable skin adhesive and gel electrolyte for continuous glucose monitoring

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 86
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorKang, Joohyukko
dc.contributor.authorKim, Kyung Yeunko
dc.contributor.authorKim, Seungwanko
dc.contributor.authorHong, Hyejunko
dc.contributor.authorBae, Byeong-Sooko
dc.contributor.authorKang, Seung-Kyunko
dc.contributor.authorLee, Wonryungko
dc.date.accessioned2024-01-03T06:01:04Z-
dc.date.available2024-01-03T06:01:04Z-
dc.date.created2024-01-03-
dc.date.created2024-01-03-
dc.date.created2024-01-03-
dc.date.issued2023-10-
dc.identifier.citationDevice, v.1, no.4-
dc.identifier.issn2666-9986-
dc.identifier.urihttp://hdl.handle.net/10203/317285-
dc.description.abstractWearable microneedle electrochemical sensors require functional soft materials such as gel electrolytes and skin adhesives to electrically and physically integrate with the skin for continuous measurements. However, current patterning methods for these materials have low process compatibility and are generally laborious and time-consuming, making it challenging to use them for various types of devices. Here, we demonstrate a conformable microneedle sensor applied using a photopatternable gel electrolyte and skin adhesive for glucose monitoring. We used oxygen inhibition photolithography to pattern the gel electrolyte and modified a thermocurable adhesive for positive photolithography, enabling precise and direct deposition onto a microneedle substrate. The resulting microneedle sensor establishes a stable electrical and physical interface with skin and is highly sensitive over a broad range of glucose concentrations. We tested the microneedle sensor for diagnosing hyperglycemia in an anesthetized rat through stable, continuous glucose monitoring.-
dc.languageEnglish-
dc.publisherElsevier BV-
dc.titleA conformable microneedle sensor with photopatternable skin adhesive and gel electrolyte for continuous glucose monitoring-
dc.typeArticle-
dc.identifier.scopusid2-s2.0-85184184688-
dc.type.rimsART-
dc.citation.volume1-
dc.citation.issue4-
dc.citation.publicationnameDevice-
dc.identifier.doi10.1016/j.device.2023.100112-
dc.contributor.localauthorBae, Byeong-Soo-
dc.contributor.nonIdAuthorKang, Joohyuk-
dc.contributor.nonIdAuthorKim, Kyung Yeun-
dc.contributor.nonIdAuthorKim, Seungwan-
dc.contributor.nonIdAuthorHong, Hyejun-
dc.contributor.nonIdAuthorKang, Seung-Kyun-
dc.contributor.nonIdAuthorLee, Wonryung-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorDTI-3: Develop-
dc.subject.keywordAuthorflexible biosensor-
dc.subject.keywordAuthorgel electrolyte-
dc.subject.keywordAuthorglucose sensor-
dc.subject.keywordAuthormicroneedle-
dc.subject.keywordAuthornonvolatile gel-
dc.subject.keywordAuthorphotopatternable material-
dc.subject.keywordAuthorskin adhesive-
dc.subject.keywordAuthorskin-intefaced wearables-
Appears in Collection
MS-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0