A preliminary study on real-time Rn/Tn discriminative detection using air-flow delay in two ion chambers in series

Cited 1 time in webofscience Cited 0 time in scopus
  • Hit : 415
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorDas, Sopanko
dc.contributor.authorKim, Junhyeokko
dc.contributor.authorPark, Jaehyunko
dc.contributor.authorChang, Hojongko
dc.contributor.authorCho, Gyuseongko
dc.date.accessioned2022-12-11T06:00:15Z-
dc.date.available2022-12-11T06:00:15Z-
dc.date.created2022-12-11-
dc.date.created2022-12-11-
dc.date.issued2022-12-
dc.identifier.citationNUCLEAR ENGINEERING AND TECHNOLOGY, v.54, no.12, pp.4644 - 4651-
dc.identifier.issn1738-5733-
dc.identifier.urihttp://hdl.handle.net/10203/302727-
dc.description.abstractDue to its short half-life, thoron gas has been assumed to have negligible health hazards on humans compared to radon. But, one of the decay products with a long half-life can make it to be transported to a long distance and to cause a severe internal dose through respiration. Since most commercial radon detectors can not discriminate thoron signals from radon signals, it is very common to overestimate radon doses which in turn result in biased estimation of lung cancer risk in epidemiological studies. Though some methods had been suggested to measure thoron and radon separately, they could not be used for real-time measurement because of CR-39 or LR-115. In this study, an effective method was suggested to measure radon and thoron separately from the free air. It was observed that the activity of thoron decreases exponentially due to delay time caused by a long pipe between two chambers. Therefore from two ion chambers apart in time, it was demonstrated that thoron and radon could be measured separately and simultaneously. We also developed a collimated alpha source and with this source and an SBD, we could convert the ion chamber reading to count rate in cps.-
dc.languageEnglish-
dc.publisherKOREAN NUCLEAR SOC-
dc.titleA preliminary study on real-time Rn/Tn discriminative detection using air-flow delay in two ion chambers in series-
dc.typeArticle-
dc.identifier.wosid000903546400012-
dc.identifier.scopusid2-s2.0-85138786906-
dc.type.rimsART-
dc.citation.volume54-
dc.citation.issue12-
dc.citation.beginningpage4644-
dc.citation.endingpage4651-
dc.citation.publicationnameNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.identifier.doi10.1016/j.net.2022.07.019-
dc.identifier.kciidART002902851-
dc.contributor.localauthorChang, Hojong-
dc.contributor.localauthorCho, Gyuseong-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorRadon-
dc.subject.keywordAuthorThoron-
dc.subject.keywordAuthorDiscriminative measurement-
dc.subject.keywordAuthorIon chamber-
dc.subject.keywordAuthorAir-flow delay-
Appears in Collection
RIMS Journal PapersNE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 1 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0