Model for estimating the penetration depth limit of the time-reversed ultrasonically encoded optical focusing technique

Cited 18 time in webofscience Cited 17 time in scopus
  • Hit : 335
  • Download : 0
The time-reversed ultrasonically encoded (TRUE) optical focusing technique is a method that is capable of focusing light deep within a scattering medium. This theoretical study aims to explore the depth limits of the TRUE technique for biological tissues in the context of two primary constraints - the safety limit of the incident light fluence and a limited TRUE's recording time (assumed to be 1 ms), as dynamic scatterer movements in a living sample can break the time-reversal scattering symmetry. Our numerical simulation indicates that TRUE has the potential to render an optical focus with a peak-to-background ratio of similar to 2 at a depth of similar to 103 mm at wavelength of 800 nm in a phantom with tissue scattering characteristics. This study sheds light on the allocation of photon budget in each step of the TRUE technique, the impact of low signal on the phase measurement error, and the eventual impact of the phase measurement error on the strength of the TRUE optical focus. (C) 2014 Optical Society of America
Publisher
OPTICAL SOC AMER
Issue Date
2014-03
Language
English
Article Type
Article
Citation

OPTICS EXPRESS, v.22, no.5, pp.5787 - 5807

ISSN
1094-4087
DOI
10.1364/OE.22.005787
URI
http://hdl.handle.net/10203/268703
Appears in Collection
BiS-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 18 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0