Analysis about a bio-mimetic three-layer skin pad structure that can improve the functionality of prosthetic hands의수의 기능성을 향상 시킬 수 있는 인체모사 3층 피부 구조체에 대한 분석

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 475
  • Download : 0
DC FieldValueLanguage
dc.contributor.advisorPark, Hyung-Soon-
dc.contributor.advisor박형순-
dc.contributor.authorHeo, Si-Hwan-
dc.date.accessioned2019-08-28T02:43:27Z-
dc.date.available2019-08-28T02:43:27Z-
dc.date.issued2018-
dc.identifier.urihttp://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=733763&flag=dissertationen_US
dc.identifier.urihttp://hdl.handle.net/10203/265861-
dc.description학위논문(석사) - 한국과학기술원 : 기계공학과, 2018.2,[v, 57 p. :]-
dc.description.abstractRecently, a prosthetic hand is now popular to most amputee patients. There have been many researches to develop various mechanism. However, in contrast to the various mechanism, skin structure have been only considered for a cosmetic role. However, in the case of human hands, the mechanical properties of human skin is thought to contribute to the overall hand function. From this perspective, we developed three-layered skin pad structure which can improve the functionality of prosthetic hands. The properties of human skin was measured based on the skin pad model that has outer skin layer/subcutaneous fat layer/muscle layer. As a result, the non-linear stiffness characteristics of human skin pad was figured out. Based on this result, we suggested the three-layer skin structure, and verified its advantages on the functionality of prosthetic hands by finite element simulation and experiment. To evaluate the functionality, the stability and manipulability indexes was suggested through observing the responses against the external wrench while the object was grasped through the skin structure. Comparing with the conventional skin structure (single-layer) in various conditions, we verified that the suggested bio-mimetic three-layer skin pad structure could improve the stability and manipulability. Also, we verified that the stiffness change of conventional skin structure could not achieve these functionality.-
dc.languageeng-
dc.publisher한국과학기술원-
dc.subjectArtificial skin▼aProsthetic hand▼aBio-mimetic▼aSilicone structure▼aMulti-layer structure-
dc.subject인공 피부▼a의수▼a생체 모사▼a실리콘 구조체▼a다층 구조체-
dc.titleAnalysis about a bio-mimetic three-layer skin pad structure that can improve the functionality of prosthetic hands-
dc.title.alternative의수의 기능성을 향상 시킬 수 있는 인체모사 3층 피부 구조체에 대한 분석-
dc.typeThesis(Master)-
dc.identifier.CNRN325007-
dc.description.department한국과학기술원 :기계공학과,-
dc.contributor.alternativeauthor허시환-
Appears in Collection
ME-Theses_Master(석사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0