Cell-Based Galactosemia Diagnosis System Based on a Galactose Assay Using a Bioluminescent Escherichia coli Array

Cited 10 time in webofscience Cited 11 time in scopus
  • Hit : 196
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorWoo, Min-Ahko
dc.contributor.authorKim, Moon Ilko
dc.contributor.authorCho, Daeyeonko
dc.contributor.authorPark, Hyun Gyuko
dc.date.accessioned2016-04-20T07:04:06Z-
dc.date.available2016-04-20T07:04:06Z-
dc.date.created2013-12-23-
dc.date.created2013-12-23-
dc.date.created2013-12-23-
dc.date.issued2013-11-
dc.identifier.citationANALYTICAL CHEMISTRY, v.85, no.22, pp.11083 - 11089-
dc.identifier.issn0003-2700-
dc.identifier.urihttp://hdl.handle.net/10203/205674-
dc.description.abstractA new cell-based galactose assay system, which is comprised of two bioluminescent Escherichia coli strains immobilized within an agarose gel arrayed on a well plate, has been developed. For this purpose, a galT knockout strain [galT(-) cell] of E. coli was genetically constructed so that cell growth is not promoted by galactose but rather by glucose present in a sample. Another E. coli W strain (normal cell), which grows normally in the presence of either glucose or galactose, was employed. A luminescent reporter gene, which produces luminescence as cells grow, was inserted into both of the E. coli strains, so that cell growth could be monitored in a facile manner. The two strains were separately grown for 4 h on gel arrays to which test samples were individually supplied. The relative luminescence unit (RLU) values caused by cell growth were determined for each array, one of which is resulted by glucose only and the other of which is resulted by both glucose and galactose present in the sample. By employing this protocol, galactose concentrations present in the test sample are reflected in the differences between the RLU values for each array. The practical utility of the new assay system was demonstrated by its use in determining galactose levels in clinical blood spot specimens coming from newborn babies. Because it can be employed to diagnosis of galactosemia in newborn babies in a more rapid, convenient, and cost-effective manner, this cell-based solid-phase galactose assay system should become a powerful alternative to conventional methods, which require labor-intensive and time-consuming procedures and/or complicated and expensive equipment.-
dc.languageEnglish-
dc.publisherAMER CHEMICAL SOC-
dc.titleCell-Based Galactosemia Diagnosis System Based on a Galactose Assay Using a Bioluminescent Escherichia coli Array-
dc.typeArticle-
dc.identifier.wosid000327360900065-
dc.identifier.scopusid2-s2.0-84888317725-
dc.type.rimsART-
dc.citation.volume85-
dc.citation.issue22-
dc.citation.beginningpage11083-
dc.citation.endingpage11089-
dc.citation.publicationnameANALYTICAL CHEMISTRY-
dc.identifier.doi10.1021/ac4027912-
dc.contributor.localauthorPark, Hyun Gyu-
dc.contributor.nonIdAuthorWoo, Min-Ah-
dc.contributor.nonIdAuthorCho, Daeyeon-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordPlusPULSED AMPEROMETRIC DETECTION-
dc.subject.keywordPlusTANDEM MASS-SPECTROMETRY-
dc.subject.keywordPlusMETABOLISM-
dc.subject.keywordPlusQUANTIFICATION-
dc.subject.keywordPlusCHROMATOGRAPHY-
dc.subject.keywordPlusAUXOTROPHS-
dc.subject.keywordPlusACID-
Appears in Collection
CBE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 10 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0