Stent length is a contributing factor of suboptimal stent expansion in drug-eluting stents

Cited 1 time in webofscience Cited 1 time in scopus
  • Hit : 221
  • Download : 518
DC FieldValueLanguage
dc.contributor.authorKim, Byung Gyuko
dc.contributor.authorCho, Sung Wooko
dc.contributor.authorKim, Deok Heeko
dc.contributor.authorKim, Jeong Hoonko
dc.contributor.authorByun, YSko
dc.contributor.authorGoh, Choong Wonko
dc.contributor.authorRhee, Kun Jooko
dc.contributor.authorLee, Byoung Kwonko
dc.contributor.authorKim, Byung Okko
dc.date.accessioned2016-04-15T03:13:35Z-
dc.date.available2016-04-15T03:13:35Z-
dc.date.created2015-09-14-
dc.date.created2015-09-14-
dc.date.issued2015-
dc.identifier.citationKARDIOLOGIA POLSKA, v.73, no.8, pp.598 - 605-
dc.identifier.issn0022-9032-
dc.identifier.urihttp://hdl.handle.net/10203/204056-
dc.description.abstractBackground: Failure to achieve optimal stent expansion poses a risk of treatment failure in percutaneous coronary intervention (PCI). Although intravascular ultrasound provides useful information for suboptimal stent expansion, a substantial portion of PCIs are currently being performed under angiographic guidance only. Aim: In order to evaluate the adequacy of stent expansion of four widely used drug-eluting stents in angiography-guided PCI, we performed a retrospective analysis of lesions undergoing PCI using quantitative coronary angiography. Methods: A total of 112 de novo lesions were analysed. Minimal lumen diameter (MLD) was measured at peak pressure during stent deployment (MLD1), after stent deployment (MLD2), and after postdilatation (MLD3). Stent underexpansion, stent elastic recoil, and stent deficit were calculated. Optimal stent deployment was defined as final MLD >= 90% of predicted diameter. Results: For deploying a stent balloon, higher than nominal pressure was used in 83% of cases (93/112). However, optimal deployment was observed in only 32% (36/112). Adjuvant post-dilatation was performed in 59% (45/76) of lesions with suboptimal expansion, which increased the optimal deployment rate by 60% (27/45). Final optimal stent deployment rate was achieved in 56% (63/112). We found that the MLD1 (p = 0.04), MLD3 (p = 0.02), final MLD (p = 0.04), and optimal stent deployment rate (p = 0.036) were significantly reduced in longer stent deployment lesions (= 20 mm) compared to shorter lesions (< 20 mm). Conclusions: Stent length may be a contributing factor of suboptimal stent expansion in angiography-guided PCI.-
dc.languageEnglish-
dc.publisherVIA MEDICA-
dc.subjectQUANTITATIVE CORONARY-ANGIOGRAPHY-
dc.subjectINTRAVASCULAR ULTRASOUND-
dc.subjectNONCOMPLIANT BALLOON-
dc.subjectIMPLANTATION-
dc.subjectRESTENOSIS-
dc.subjectUNDEREXPANSION-
dc.subjectGUIDANCE-
dc.subjectTRIAL-
dc.subjectDEPLOYMENT-
dc.subjectINFLATION-
dc.titleStent length is a contributing factor of suboptimal stent expansion in drug-eluting stents-
dc.typeArticle-
dc.identifier.wosid000360131800003-
dc.identifier.scopusid2-s2.0-84940102982-
dc.type.rimsART-
dc.citation.volume73-
dc.citation.issue8-
dc.citation.beginningpage598-
dc.citation.endingpage605-
dc.citation.publicationnameKARDIOLOGIA POLSKA-
dc.identifier.doi10.5603/KP.a2015.0034-
dc.contributor.nonIdAuthorKim, Byung Gyu-
dc.contributor.nonIdAuthorKim, Deok Hee-
dc.contributor.nonIdAuthorKim, Jeong Hoon-
dc.contributor.nonIdAuthorByun, YS-
dc.contributor.nonIdAuthorGoh, Choong Won-
dc.contributor.nonIdAuthorRhee, Kun Joo-
dc.contributor.nonIdAuthorLee, Byoung Kwon-
dc.contributor.nonIdAuthorKim, Byung Ok-
dc.description.isOpenAccessY-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorstent expansion-
dc.subject.keywordAuthorquantitative coronary angiography-
dc.subject.keywordAuthorpercutaneous coronary intervention-
dc.subject.keywordPlusQUANTITATIVE CORONARY-ANGIOGRAPHY-
dc.subject.keywordPlusINTRAVASCULAR ULTRASOUND-
dc.subject.keywordPlusNONCOMPLIANT BALLOON-
dc.subject.keywordPlusIMPLANTATION-
dc.subject.keywordPlusRESTENOSIS-
dc.subject.keywordPlusUNDEREXPANSION-
dc.subject.keywordPlusGUIDANCE-
dc.subject.keywordPlusTRIAL-
dc.subject.keywordPlusDEPLOYMENT-
dc.subject.keywordPlusINFLATION-
Appears in Collection
Files in This Item
000360131800003.pdf(349.83 kB)Download
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 1 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0