Current density dependence on performance degradation of direct methanol fuel cells

Cited 62 time in webofscience Cited 61 time in scopus
  • Hit : 497
  • Download : 187
A stability test on direct methanol fuel cells (DMFCs) was carried out at current densities of 100, 150, and 200 mA cm(-2). Each test lasted for 145 h in the three cases. X-ray diffraction, energy dispersive spectroscopy, and scanning electron microscopy were used for analysis of the membrane electrode assemblies (MEAs). The maximum power densities were 93.9, 79.9, and 55.1% of the initial value after operation at 100, 150, and 200 mA cm(-2), respectively. A PtRu black catalyst with an original particle size of 3.3 nm was used for the anode electrode. For the MEAs operated at 100, 150, and 200 mA cm(-2), the PtRu particle sizes increased from the original size to 3.4, 3.9, and 4.2 nm, respectively, while a Pt black catalyst used for the cathode electrode did not change in size. Dissolution of the Ru was observed, and the ratio of (Pt:Ru) changed from (53:47) in the case of the fresh MEA, to (54:46), (56:44), and (73:27) for the MEAs after operation at 100, 150, and 200 mA cm(-2), respectively. The equivalent weight of the Nafion (TM) membrane increased from a weight of 1264 g for a fresh membrane, to a weight of 1322, 1500, and 1945 g with the increases in operating current density to 100, 150, and 200 mA cm(-2), respectively. (c) 2005 Elsevier B.V. All rights reserved.
Publisher
ELSEVIER SCIENCE BV
Issue Date
2006-08
Language
English
Article Type
Article
Keywords

OXIDATION

Citation

JOURNAL OF POWER SOURCES, v.158, no.2, pp.1344 - 1347

ISSN
0378-7753
DOI
10.1016/j.jpowsour.2005.10.056
URI
http://hdl.handle.net/10203/18474
Appears in Collection
CBE-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 62 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0