A 4.78 mu s Dynamic Compensated Inductive Coupling Transceiver for Ubiquitous and Wearable Body Sensor Network

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 419
  • Download : 11
A Real time Capacitor Compensation (RCC) scheme is proposed for low power and continuous communication in the wearable inductive coupling transceiver Since inductance values of wearable inductor vary dynamically with deterioration of its communication characteristics the inductance value is monitored and its resonance frequency is adjusted by additive parallel/serial capacitors in real time RLC Bridge for detection of the inductance variations and the Dual edge Sampling Comparator for recognition of the variance direction are proposed It is Implemented in a 0 18 mu m CMOS technology and it occupies a 1 x 2 7 mm(2) chip area The proposed transceiver consumes only 426 6 mu W at 4 Mbps data rate The compensation time takes 4 78 mu s including 3 mu s of detection and 1 78 mu s for compensation process in worst case
Publisher
IEICE-INST ELECTRONICS INFORMATION COMMUNICATIONS ENG
Issue Date
2010-11
Language
English
Article Type
Article
Keywords

CIRCUIT

Citation

IEICE TRANSACTIONS ON COMMUNICATIONS, v.E93B, pp.2892 - 2900

ISSN
0916-8516
DOI
10.1587/transcom.E93.B.2892