Investigation of helium injection cooling to liquid oxygen propellant chamber

Cited 18 time in webofscience Cited 0 time in scopus
  • Hit : 442
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorCho, Nko
dc.contributor.authorKwon, Oko
dc.contributor.authorKim, Yko
dc.contributor.authorJeong, Sangkwonko
dc.date.accessioned2013-03-08T03:18:23Z-
dc.date.available2013-03-08T03:18:23Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2006-02-
dc.identifier.citationCRYOGENICS, v.46, pp.132 - 142-
dc.identifier.issn0011-2275-
dc.identifier.urihttp://hdl.handle.net/10203/91972-
dc.description.abstractSub-cooling of cryogenic propellant by helium injection is one of the most effective methods for suppressing bulk boiling and keeping sub-cooled liquid oxygen before rocket launch. In order to design the cooling system, understanding of the limitations of heat and mass transfer is required. In this paper, an analytical model for the helium injection system is presented. This model's main feature is the representation of bubbling system using finite-rate heat transfer and instantaneous mass transfer concept. With this simplified approach, the effect of helium injection to liquid oxygen system under several circumstances is examined. Experimental results along with simulations of single bubble rising in liquid oxygen and bubbling system are presented with various helium injection flow rates, helium temperatures, and injection methods. The overall cooling effect for rocket application is also discussed. (C) 2005 Elsevier Ltd. All rights reserved.-
dc.languageEnglish-
dc.publisherELSEVIER SCI LTD-
dc.titleInvestigation of helium injection cooling to liquid oxygen propellant chamber-
dc.typeArticle-
dc.identifier.wosid000236092400010-
dc.identifier.scopusid2-s2.0-33244460124-
dc.type.rimsART-
dc.citation.volume46-
dc.citation.beginningpage132-
dc.citation.endingpage142-
dc.citation.publicationnameCRYOGENICS-
dc.contributor.localauthorJeong, Sangkwon-
dc.contributor.nonIdAuthorCho, N-
dc.contributor.nonIdAuthorKwon, O-
dc.contributor.nonIdAuthorKim, Y-
dc.type.journalArticleArticle; Proceedings Paper-
dc.subject.keywordAuthorhelium injection-
dc.subject.keywordAuthorsub-cooling-
dc.subject.keywordAuthordiffusion-
dc.subject.keywordAuthorliquid oxygen-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 18 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0