맥동압력조건에서 재생기를 통한 왕복유동의 압력강하 특성에 대한 연구Investigation on the pressure drop characteristics of oscillating flow through regenerators under pulsating pressure conditions

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 391
  • Download : 0
This paper proposes a new oscillating flow model of the pressure drop through the regenerator under pulsating pressure. In this oscillating flow model. pressure drop is expressed by the amplitude and the phase angle with respect to the inlet mass flow rate. In order to generalize the oscillating flow model. non-dimensional parameters, which are Reynolds number, Valensi number, gas domain length ratio, oscillating flow friction factor and phase angle of pressure drop, are derived from the capillary tube model of the regenerator. Correlations for the oscillating flow friction factor and the phase angle are obtained from the experiments for the twill-square screen regenerators under various operating frequencies and inlet mass flow rates. The oscillating friction factor is a function of the Reynolds number alone and the phase angle of pressure drop is a function of the Valensi number and the gas domain length ratio. Experiment is also performed to examine the effect of the weave style of screen. Experimental data demonstrate the superiority of the oscillating flow model over the previous steady flow model.
Publisher
한국초전도ㆍ저온공학회
Issue Date
2003
Language
Korean
Citation

한국초전도·저온공학회논문지, v.5, no.2, pp.51 - 57