DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Dae Yong | ko |
dc.contributor.author | Joe, Daniel Juhyung | ko |
dc.contributor.author | Kim, Dong Hyun | ko |
dc.contributor.author | Park, Hyewon | ko |
dc.contributor.author | Han, Jae Hyun | ko |
dc.contributor.author | Jeong, Chang Kyu | ko |
dc.contributor.author | Park, Hyelim | ko |
dc.contributor.author | Park, Jung Gyu | ko |
dc.contributor.author | Joung, Boyoung | ko |
dc.contributor.author | Lee, Keon Jae | ko |
dc.date.accessioned | 2017-11-08T02:21:52Z | - |
dc.date.available | 2017-11-08T02:21:52Z | - |
dc.date.created | 2017-10-23 | - |
dc.date.created | 2017-10-23 | - |
dc.date.issued | 2017-10 | - |
dc.identifier.citation | ADVANCED MATERIALS, v.29, no.37 | - |
dc.identifier.issn | 0935-9648 | - |
dc.identifier.uri | http://hdl.handle.net/10203/226711 | - |
dc.description.abstract | Continuous monitoring of an arterial pulse using a pressure sensor attached on the epidermis is an important technology for detecting the early onset of cardiovascular disease and assessing personal health status. Conventional pulse sensors have the capability of detecting human biosignals, but have significant drawbacks of power consumption issues that limit sustainable operation of wearable medical devices. Here, a self-powered piezoelectric pulse sensor is demonstrated to enable in vivo measurement of radial/ carotid pulse signals in near-surface arteries. The inorganic piezoelectric sensor on an ultrathin plastic achieves conformal contact with the complex texture of the rugged skin, which allows to respond to the tiny pulse changes arising on the surface of epidermis. Experimental studies provide characteristics of the sensor with a sensitivity (approximate to 0.018 kPa(-1)), response time (approximate to 60 ms), and good mechanical stability. Wireless transmission of detected arterial pressure signals to a smart phone demonstrates the possibility of self-powered and real-time pulse monitoring system. | - |
dc.language | English | - |
dc.publisher | WILEY-V C H VERLAG GMBH | - |
dc.subject | TRIBOELECTRIC NANOGENERATOR | - |
dc.subject | THIN-FILMS | - |
dc.subject | PRESSURE SENSORS | - |
dc.subject | HIGH-RESOLUTION | - |
dc.subject | STRAIN SENSOR | - |
dc.subject | ELECTRONICS | - |
dc.subject | ENERGY | - |
dc.subject | ARRAY | - |
dc.subject | PERFORMANCE | - |
dc.subject | HEALTH | - |
dc.title | Self-Powered Real-Time Arterial Pulse Monitoring Using Ultrathin Epidermal Piezoelectric Sensors | - |
dc.type | Article | - |
dc.identifier.wosid | 000412184100014 | - |
dc.identifier.scopusid | 2-s2.0-85024112434 | - |
dc.type.rims | ART | - |
dc.citation.volume | 29 | - |
dc.citation.issue | 37 | - |
dc.citation.publicationname | ADVANCED MATERIALS | - |
dc.identifier.doi | 10.1002/adma.201702308 | - |
dc.contributor.localauthor | Joe, Daniel Juhyung | - |
dc.contributor.localauthor | Lee, Keon Jae | - |
dc.contributor.nonIdAuthor | Park, Hyewon | - |
dc.contributor.nonIdAuthor | Park, Hyelim | - |
dc.contributor.nonIdAuthor | Park, Jung Gyu | - |
dc.contributor.nonIdAuthor | Joung, Boyoung | - |
dc.description.isOpenAccess | N | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordAuthor | arterial pulse monitoring | - |
dc.subject.keywordAuthor | laser lift-off | - |
dc.subject.keywordAuthor | real-time monitoring | - |
dc.subject.keywordAuthor | self-powered | - |
dc.subject.keywordAuthor | ultrathin piezoelectric sensors | - |
dc.subject.keywordPlus | TRIBOELECTRIC NANOGENERATOR | - |
dc.subject.keywordPlus | THIN-FILMS | - |
dc.subject.keywordPlus | PRESSURE SENSORS | - |
dc.subject.keywordPlus | HIGH-RESOLUTION | - |
dc.subject.keywordPlus | STRAIN SENSOR | - |
dc.subject.keywordPlus | ELECTRONICS | - |
dc.subject.keywordPlus | ENERGY | - |
dc.subject.keywordPlus | ARRAY | - |
dc.subject.keywordPlus | PERFORMANCE | - |
dc.subject.keywordPlus | HEALTH | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.