A split and recombination micromixer fabricated in a PDMS three-dimensional structure

Cited 103 time in webofscience Cited 0 time in scopus
  • Hit : 785
  • Download : 81
DC FieldValueLanguage
dc.contributor.authorLee, Seok Wooko
dc.contributor.authorKim, Dong Sungko
dc.contributor.authorLee, Seung Seobko
dc.contributor.authorKwon, Tai Hunko
dc.date.accessioned2007-11-06T07:47:47Z-
dc.date.available2007-11-06T07:47:47Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2006-05-
dc.identifier.citationJOURNAL OF MICROMECHANICS AND MICROENGINEERING, v.16, no.5, pp.1067 - 1072-
dc.identifier.issn0960-1317-
dc.identifier.urihttp://hdl.handle.net/10203/1834-
dc.description.abstractIn this paper we propose a new split and recombination (SAR) micromixer that is compatible with the microfabrication process of polydimethylsiloxane ( PDMS). We evaluate the mixing efficiency of the fabricated SAR micromixer and find that it increases interfaces exponentially. Simulation using CFD-ACE+ shows a cross-sectional view of the flow and estimates the mixing efficiency of the SAR micromixer and the pressure drop for a unit of the SAR micromixer. A mixing experiment involving phenolphthalein and NaOH solutions shows that interfaces, represented as red lines, are increased by SAR mixing. The result of our mixing experiment involving blue dye and water is evaluated to determine the mixing efficiency by calculating the standard deviation (stdev) of the pixel intensity of the observed image. After the seventh unit of the SAR micromixer, solutions are mixed to 90% at Re 0.6. The number of units needed to reach a mixed state in which the stdev is lower than 0.05, a 90% mixed state, increases from 5 to 10 for a flow rate ranging from 0.1 mu l min(-1) (Re 0.012) to 1000 mu l min(-1) ( Re 120) including numerical analysis results. The pressure drop increases proportionally from 2.8 Pa to 35 000 Pa when the flow rate increases from 0.1 mu l min(-1) (Re 0.012) to 1000 mu l min(-1) ( Re 120) in the numerical analysis results.-
dc.languageEnglish-
dc.language.isoen_USen
dc.publisherIOP PUBLISHING LTD-
dc.subjectMICROCHANNEL-
dc.subjectMICROPUMP-
dc.subjectSYSTEMS-
dc.subjectMIXER-
dc.titleA split and recombination micromixer fabricated in a PDMS three-dimensional structure-
dc.typeArticle-
dc.identifier.wosid000238124300028-
dc.identifier.scopusid2-s2.0-33744465250-
dc.type.rimsART-
dc.citation.volume16-
dc.citation.issue5-
dc.citation.beginningpage1067-
dc.citation.endingpage1072-
dc.citation.publicationnameJOURNAL OF MICROMECHANICS AND MICROENGINEERING-
dc.identifier.doi10.1088/0960-1317/16/5/027-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.contributor.localauthorLee, Seung Seob-
dc.contributor.nonIdAuthorLee, Seok Woo-
dc.contributor.nonIdAuthorKim, Dong Sung-
dc.contributor.nonIdAuthorKwon, Tai Hun-
dc.type.journalArticleArticle-
dc.subject.keywordPlusMICROCHANNEL-
dc.subject.keywordPlusMICROPUMP-
dc.subject.keywordPlusSYSTEMS-
dc.subject.keywordPlusMIXER-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button