SiC 필라멘트를 이용한 소염 직전의 확산화염 온도 계측SiC Filament Pyrometry in Near Extinction Diffusion Flame

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 329
  • Download : 2
The thin SiC filament technique has been employed to identify the possibility of measuring flame temperature, and especially unstable near-extinction flame temperature in an oxidizer deficient ambience, by comparing the relative visible (non-IR) luminosities of SiC filaments with thermocouple measured temperature in co-flowing, laminar propane/air diffusion flames. The results show good agreement between the digitized relative visible luminosity profiles of the SiC filaments and temperature profiles measured using a thermocouple at temperatures above 700℃, although, a non-linear calibration is probably required far the whole temperature range. The highest radial peak temperature exists near to the nozzle exit. and the centerline temperatures were virtually unchanged with increasing flame height in an oxidizer deficient near-extinction flame
Publisher
대한기계학회
Issue Date
2002-11
Language
Korean
Citation

대한기계학회논문집 B, v.26, no.11, pp.1481 - 1487