Quantitation of Surface-bound Proteins on Biochips Using MALDI-TOF MS

Cited 7 time in webofscience Cited 0 time in scopus
  • Hit : 469
  • Download : 627
We report on a novel method for the quantitation of proteins specifically bound on a ligand-presenting biochip by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS). The bound protein was digested by trypsin, and the resulting peptide fragments were analyzed by MALDI-TOF MS in the presence of an isotope-labeled internal standard (IS). The IS has the same sequence as a reference peptide (RP) of the target protein digest, but a different molecular weight. The absolute amount of the specifically bound protein on a biochip is then quantitated by comparison of mass intensities between the RP and the IS. Because they have the same molecular milieu, the mass intensities of these two analytes represent the real amounts of analytes on the chip. As a model system, we tested glutathione s-transferase (GST) and a GST-fusion protein, which were captured on glutathione-presenting biochips. We observed that the glutathione densities on biochips showed a good correlation with the absolute quantity of the proteins. We believe that our method will provide an alternative to currently existing tools for the absolute quantitation of surface-bound proteins.
Publisher
Japan Soc Analytical Chemistry
Issue Date
2011-11
Language
English
Article Type
Article
Keywords

PLASMON RESONANCE; MASS-SPECTROMETRY; QUANTIFICATION; MICROARRAYS; ADSORPTION; CHIPS

Citation

ANALYTICAL SCIENCES, v.27, no.11, pp.1127 - 1131

ISSN
0910-6340
URI
http://hdl.handle.net/10203/95261
Appears in Collection
CH-Journal Papers(저널논문)
Files in This Item
66277.pdf(731.17 kB)Download
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 7 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0