Feasibility study on many-view under-sampling technique for low-dose computed tomography

Cited 21 time in webofscience Cited 0 time in scopus
  • Hit : 343
  • Download : 891
DC FieldValueLanguage
dc.contributor.authorCho, Seungryongko
dc.contributor.authorLee, Taewonko
dc.contributor.authorMin, Jonghwanko
dc.contributor.authorChung, Hyekyunko
dc.date.accessioned2013-03-08T17:37:08Z-
dc.date.available2013-03-08T17:37:08Z-
dc.date.created2012-11-29-
dc.date.created2012-11-29-
dc.date.issued2012-08-
dc.identifier.citationOPTICAL ENGINEERING, v.51, no.8-
dc.identifier.issn0091-3286-
dc.identifier.urihttp://hdl.handle.net/10203/93771-
dc.description.abstractWe proposed a novel scanning method for low-dose computed tomography (CT) that uses an oscillating multi-slit collimator between the x-ray source and the patient. It can be thought as a realization of sparse data sampling that does not require a fast x-ray power switching. A simulation study was performed based on experimentally acquired microCT data of a mouse to demonstrate the feasibility of the proposed method. A numerical collimation was designed to leave only one-fourth of each projection data for use in image reconstruction. A total-variation minimization algorithm was implemented for image reconstruction from the sparely sampled data. We have successfully shown that the proposed method provides a viable option to low-dose CT. (c) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.OE.51.8.080501]-
dc.languageEnglish-
dc.publisherSPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS-
dc.subjectIMAGE-RECONSTRUCTION-
dc.subjectCT-
dc.titleFeasibility study on many-view under-sampling technique for low-dose computed tomography-
dc.typeArticle-
dc.identifier.wosid000309913000002-
dc.identifier.scopusid2-s2.0-84880560690-
dc.type.rimsART-
dc.citation.volume51-
dc.citation.issue8-
dc.citation.publicationnameOPTICAL ENGINEERING-
dc.identifier.doi10.1117/1.OE.51.8.080501-
dc.contributor.localauthorCho, Seungryong-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorcomputed tomography-
dc.subject.keywordAuthorimage reconstruction-
dc.subject.keywordAuthorlow-dose-
dc.subject.keywordAuthorcollimator-
dc.subject.keywordPlusIMAGE-RECONSTRUCTION-
dc.subject.keywordPlusCT-
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 21 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0