Remediation for buried pipeline systems under permanent ground deformation

Cited 54 time in webofscience Cited 0 time in scopus
  • Hit : 286
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorChoo, Yun Wookko
dc.contributor.authorAbdoun, Tarek H.ko
dc.contributor.authorO'Rourke, Micheal J.ko
dc.contributor.authorHa, Dako
dc.date.accessioned2013-03-08T12:57:08Z-
dc.date.available2013-03-08T12:57:08Z-
dc.date.created2012-10-25-
dc.date.created2012-10-25-
dc.date.issued2007-12-
dc.identifier.citationSOIL DYNAMICS AND EARTHQUAKE ENGINEERING, v.27, pp.1043 - 1055-
dc.identifier.issn0267-7261-
dc.identifier.urihttp://hdl.handle.net/10203/93064-
dc.description.abstractA remediation technique for buried pipeline system subject to permanent ground deformation is proposed. Specifically, expanded polystyrene (EPS) geofoam blocks are used as low-density backfill, thereby reducing soil restraint and pipeline strains. In order to evaluate this remediation technique, a series of 12 centrifuge model tests with HDPE pipe was performed. The amount or spatial extent of the low-density backfill was varied, as well as the orientation of the pipe with respect to the fault offset. Specifically, in the -63.5 degrees test, the orientation was such that the pipe was placed in flexure and axial tension. The -85 degrees orientation placed the pipe mainly in flexure. In all cases, the behavior of the remediated pipe was compared to that for the unremediated pipe. The geofoam backfill was successful in improving pipe behavior for two of the three pipe/fault orientations. However, for the 60 degrees orientation, the pipe buckled in compression irrespective of the geofoam backfill. For compression, it is recommended that the pipe-fault angle be considered at the route selection stage to avoid compression loading. (C) 2007 Elsevier Ltd. All rights reserved.-
dc.languageEnglish-
dc.publisherELSEVIER SCI LTD-
dc.titleRemediation for buried pipeline systems under permanent ground deformation-
dc.typeArticle-
dc.identifier.wosid000250641100001-
dc.identifier.scopusid2-s2.0-34748869614-
dc.type.rimsART-
dc.citation.volume27-
dc.citation.beginningpage1043-
dc.citation.endingpage1055-
dc.citation.publicationnameSOIL DYNAMICS AND EARTHQUAKE ENGINEERING-
dc.contributor.nonIdAuthorAbdoun, Tarek H.-
dc.contributor.nonIdAuthorO'Rourke, Micheal J.-
dc.contributor.nonIdAuthorHa, Da-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorpipeline-
dc.subject.keywordAuthorpermanent ground deformation-
dc.subject.keywordAuthorremediation-
dc.subject.keywordAuthorcentrifuge modeling-
dc.subject.keywordAuthorlow-density backfill-
dc.subject.keywordAuthorEPS geofoam-
Appears in Collection
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 54 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0