단일 히터의 디지털 구동을 통한 유효 히터면적 변화 및 분사 액적크기 조절이 가능한 미소유체분사기Effective Heater-Area and Droplet-Volume Adjustable Microinjectors Using a Digitally Controlled Single Heater

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 605
  • Download : 0
The paper presents a single-heater microfluid injector, whose ejected droplet volume is adjusted by digital current path control for a single microheater. The previous droplet volume adjustable methods have used the digital current control for multiple heaters or the analog current control for a single heater, while the present method uses the digital current control for a single microheater. Two different microinjectors, having a rectangular heater and a circular hearter, are designed and fabricated in the chip area of $7.64\;mm{\times}5.26\;mm$. The fabricated microinjectors have been tested and characterized for the number, size, shape and lifetime of the generated bubbles as well as for the volume and velocity of the ejected droplets. The input power for the rectangular heater and the circular heater has been varied in the ranges of $8.7{\sim}24.9{\mu}W\;and\;8.1{\sim}43.8{\mu}W$, respectively. The projected area of the generated bubble has been changed in the ranges of $440{\sim}l,3600{\mu}m^2\;and\;800{\sim}3,300{\mu}m^2$ for the rectangular heater and the circular heater, respectively. The microinjector with the rectangular heater ejects three discrete levels of the droplet in the volume range of $9.4{\sim}20.7pl$ with the velocity range of $0.8{\sim}1.7m/s$, while the microinjector with the circular heater achieves five discrete levels of the droplet in the volume range of $7.4{\sim}27.4pl$ with the velocity range of $0.5{\sim}2.8m/s$.
Publisher
대한기계학회
Issue Date
2005-01
Language
Korean
Citation

대한기계학회논문집 A, v.29, no.1, pp.67 - 73

ISSN
1226-4873
URI
http://hdl.handle.net/10203/92012
Appears in Collection
BiS-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0