4-bit 디지털 미소분사기의 설계변수와 토출성능간의 영향분석에 관한 실험적 연구Design Parameters and Experimental Performance Evaluation of 4-bit Digital Multi-heater Microinjector

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 474
  • Download : 0
DC FieldValueLanguage
dc.contributor.author강태구ko
dc.contributor.author조영호ko
dc.date.accessioned2013-03-08T03:28:38Z-
dc.date.available2013-03-08T03:28:38Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2005-03-
dc.identifier.citation대한기계학회논문집 A, v.29, no.3, pp.418 - 424-
dc.identifier.issn1226-4873-
dc.identifier.urihttp://hdl.handle.net/10203/92010-
dc.description.abstractWe present the design, fabrication and experimental results of 4-bit digital microinjectors, whose ejected droplet volumes are adjusted by the digital operation of a 4-bit microheater array. We design the reference microinjectors as well as its comparative test structures. In the fabrication process, we use a five-mask micromachining process and the total chip size of the fabricated microinjector is We measure the ejected droplet volumes and velocities, which are adjusted from respectively, depending on the 15 possible combinations of 4-bit microheater array. We also experimentally characterize the effect of geometric variation including the microheater size, inter-microheater gap, microchannel width and sequential operation of microheater array on the ejected droplet volume and velocity. Among these parameters, we find that the microheater size is the most dominant parameter affected to the ejected droplet volumes and velocities. Thus, the present microinjector has a potential for application to the high-resolution inkjet printers with multiple gray levels or high-precision fluid injectors with variable volume control.-
dc.languageKorean-
dc.publisher대한기계학회-
dc.title4-bit 디지털 미소분사기의 설계변수와 토출성능간의 영향분석에 관한 실험적 연구-
dc.title.alternativeDesign Parameters and Experimental Performance Evaluation of 4-bit Digital Multi-heater Microinjector-
dc.typeArticle-
dc.type.rimsART-
dc.citation.volume29-
dc.citation.issue3-
dc.citation.beginningpage418-
dc.citation.endingpage424-
dc.citation.publicationname대한기계학회논문집 A-
dc.identifier.kciidART000956907-
dc.contributor.localauthor조영호-
dc.contributor.nonIdAuthor강태구-
dc.subject.keywordAuthor가열방식미소분사기-
dc.subject.keywordAuthor미소저항열-
dc.subject.keywordAuthor분사액적 크기조절-
dc.subject.keywordAuthor잉크젯 프린터-
dc.subject.keywordAuthorThermal Microfluid Injector-
dc.subject.keywordAuthorMicroheater Array-
dc.subject.keywordAuthorDroplet Volume Adjustment-
dc.subject.keywordAuthorInkjet Printer-