This paper presents a study conducted to develop guidelines for the design of an air bubble destratification system, with particular concern given to plume spacing. To investigate the effect of plume spacing on the destratification efficiency of the system, we first conducted a dimensional analysis that included major variables in bubble hydrodynamics. Then, we conducted laboratory experiments with various plume spacings and water depths under non-linear stratification conditions, and we evaluated the destratification efficiencies. Our results showed that the highest efficiency was obtained with a plume spacing of 0.75 times the water depth. Our study has shown that the overall efficiency of an air diffuser system can be increased by changing the spacing between diffusers and that plume spacing should be a major design parameter for future air diffuser systems.
Publisher
SELPER LTD
Issue Date
2006-10
Language
English
Article Type
Article
Keywords

STRATIFIED MULTIPHASE PLUMES; BUBBLE PLUMES; ENVIRONMENTS

Citation

ENVIRONMENTAL TECHNOLOGY, v.27, pp.1145 - 1151

ISSN
0959-3330
DOI
10.1080/09593332708618728
URI
http://hdl.handle.net/10203/89849
Appears in Collection
CE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 4 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0