DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, CW | ko |
dc.contributor.author | Lee, DH | ko |
dc.contributor.author | Kim, BH | ko |
dc.contributor.author | Park, SN | ko |
dc.contributor.author | Shin, Hyun Dong | ko |
dc.date.accessioned | 2013-03-06T21:28:36Z | - |
dc.date.available | 2013-03-06T21:28:36Z | - |
dc.date.created | 2012-02-06 | - |
dc.date.created | 2012-02-06 | - |
dc.date.issued | 2006-02 | - |
dc.identifier.citation | METROLOGIA, v.43, no.1, pp.135 - 141 | - |
dc.identifier.issn | 0026-1394 | - |
dc.identifier.uri | http://hdl.handle.net/10203/88523 | - |
dc.description.abstract | We have improved the accuracy in source-based calibration of radiative heat flux sensors by considering the temperature non-uniformity of the blackbody cavity. The method measures the responsivity of a heat flux sensor as a function of distance from the blackbody aperture. From this variation of the responsivity, the temperature distribution and the effective emissivity of the blackbody can be determined via a Monte Carlo simulation. The calibration uncertainty is evaluated to be 2.3% (k = 2) for irradiance values up to 10 kW m(-2) at a blackbody temperature around 2900 degrees C. In order to verify the accuracy improvement, the results are compared with those of a detector-based calibration, which demonstrated an agreement within the uncertainty. | - |
dc.language | English | - |
dc.publisher | IOP PUBLISHING LTD | - |
dc.subject | MONTE-CARLO METHOD | - |
dc.subject | EFFECTIVE EMISSIVITIES | - |
dc.subject | FACILITIES | - |
dc.subject | CAVITIES | - |
dc.title | Accuracy improvement in the source-based calibration of radiative heat flux sensors by consideration of the temperature non-uniformity of the high temperature blackbody | - |
dc.type | Article | - |
dc.identifier.wosid | 000236136000021 | - |
dc.identifier.scopusid | 2-s2.0-31544460711 | - |
dc.type.rims | ART | - |
dc.citation.volume | 43 | - |
dc.citation.issue | 1 | - |
dc.citation.beginningpage | 135 | - |
dc.citation.endingpage | 141 | - |
dc.citation.publicationname | METROLOGIA | - |
dc.identifier.doi | 10.1088/0026-1394/43/1/019 | - |
dc.contributor.localauthor | Shin, Hyun Dong | - |
dc.contributor.nonIdAuthor | Park, CW | - |
dc.contributor.nonIdAuthor | Lee, DH | - |
dc.contributor.nonIdAuthor | Kim, BH | - |
dc.contributor.nonIdAuthor | Park, SN | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordPlus | MONTE-CARLO METHOD | - |
dc.subject.keywordPlus | EFFECTIVE EMISSIVITIES | - |
dc.subject.keywordPlus | FACILITIES | - |
dc.subject.keywordPlus | CAVITIES | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.