DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김홍일 | ko |
dc.contributor.author | 양호순 | ko |
dc.contributor.author | 조창래 | ko |
dc.contributor.author | 조혁진 | ko |
dc.contributor.author | 김홍배 | ko |
dc.contributor.author | 한재흥 | ko |
dc.date.accessioned | 2008-12-10T01:59:05Z | - |
dc.date.available | 2008-12-10T01:59:05Z | - |
dc.date.created | 2012-02-06 | - |
dc.date.created | 2012-02-06 | - |
dc.date.issued | 2008-09 | - |
dc.identifier.citation | 한국항공우주학회지, v.36, no.9, pp.916 - 922 | - |
dc.identifier.issn | 1225-1348 | - |
dc.identifier.uri | http://hdl.handle.net/10203/8051 | - |
dc.description.abstract | Structures being used in space environment, should be designed to have minimum CTE(coefficient of thermal expansion) for the dimensional stability. Accurate CTE data of the materials are required to design the space structures consisting of various materials. There are uncertainties in the characteristics of materials even though the same manufacturing processes are applied. Therefore, it is needed to measure the thermal deformation of not only the material specimen but also substructures in simulated space environment, such as high vacuum condition. In this research, therefore, precise CTE measurement system using displacement measuring interferometer and vacuum chamber has been designed with uncertainty analysis of the measurements. This system can be used to measure the CTE of the specimen or thermal expansion of the substructure with varying size up to 50cm in length. To measure the low CTE material, overall uncertainty of this system is expected under 0.01ppm/K. | - |
dc.description.sponsorship | 한국표준과학연구원 | en |
dc.language | Korean | - |
dc.language.iso | ko | en |
dc.publisher | 한국항공우주학회 | - |
dc.title | 우주용 구조 재료의 초정밀 열팽창계수 측정시스템 설계 | - |
dc.title.alternative | Design of High-precision CTE measurement System for the Structural Materials in Space Applications | - |
dc.type | Article | - |
dc.identifier.alternativecitation | Journal of The Korean Society for Aeronautical and Space Sciences, v.36, no.9, pp.916-922 | en |
dc.publisher.alternative | The Korean Society for Aeronautical and Space Sciences | en |
dc.subject.alternative | Dimensional stability | en |
dc.subject.alternative | CTE | en |
dc.subject.alternative | Displacement measuring interferometer | en |
dc.type.rims | ART | - |
dc.citation.volume | 36 | - |
dc.citation.issue | 9 | - |
dc.citation.beginningpage | 916 | - |
dc.citation.endingpage | 922 | - |
dc.citation.publicationname | 한국항공우주학회지 | - |
dc.identifier.kciid | ART001271383 | - |
dc.contributor.localauthor | 한재흥 | - |
dc.contributor.nonIdAuthor | 김홍일 | - |
dc.contributor.nonIdAuthor | 양호순 | - |
dc.contributor.nonIdAuthor | 조창래 | - |
dc.contributor.nonIdAuthor | 조혁진 | - |
dc.contributor.nonIdAuthor | 김홍배 | - |
dc.subject.keywordAuthor | Dimensional stability(치수 안정성) | - |
dc.subject.keywordAuthor | CTE(열팽창계수) | - |
dc.subject.keywordAuthor | Displacement measuring Interferometer(변위 측정 간섭계) | - |
dc.subject.keywordAuthor | Dimensional stability(치수 안정성) | - |
dc.subject.keywordAuthor | CTE(열팽창계수) | - |
dc.subject.keywordAuthor | Displacement measuring Interferometer(변위 측정 간섭계) | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.