NMR functional imaging using a tailored RF gradient echo sequence: A true susceptibility measurement technique

Cited 16 time in webofscience Cited 12 time in scopus
  • Hit : 274
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorCho, ZHko
dc.contributor.authorRo, YongManko
dc.contributor.authorPark, STko
dc.contributor.authorChung, SCko
dc.date.accessioned2013-03-03T05:08:35Z-
dc.date.available2013-03-03T05:08:35Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued1996-01-
dc.identifier.citationMAGNETIC RESONANCE IN MEDICINE, v.35, no.1, pp.1 - 5-
dc.identifier.issn0740-3194-
dc.identifier.urihttp://hdl.handle.net/10203/77367-
dc.description.abstractThe tailored radio frequency gradient echo (TRFGE) technique that has been used in venography (Cho et al., Magn. Reson. Med. 28, 25-38, 1992; Ro, Cho, Magn. Reson. Med. 28, 237, 1992) is applied to functional imaging, The TRFGE technique has the advantage that it is sensitive to the field gradient created by the susceptibility effect, thereby enhancing only the signals from the regions with local field gradient, In addition, the method is insensitive to the in-flow effect, especially from the arterial blood. The latter further simplifies the functional MRI data analysis. The TRFGE sequence is, therefore, suitable for functional MR imaging for which true susceptibility effect measurements are of prime importance, To examine the TRFGE functional imaging systematically, experiments with various imaging parameters such as flip angle or, repetition time, and echo time were performed and the results were compared with the data obtained from the conventional gradient echo functional MR imaging, The experimental results shown were all obtained from human volunteers with a 2.0T whole body MRI system.-
dc.languageEnglish-
dc.publisherWILLIAMS WILKINS-
dc.titleNMR functional imaging using a tailored RF gradient echo sequence: A true susceptibility measurement technique-
dc.typeArticle-
dc.identifier.wosidA1996TN36800001-
dc.identifier.scopusid2-s2.0-0030032647-
dc.type.rimsART-
dc.citation.volume35-
dc.citation.issue1-
dc.citation.beginningpage1-
dc.citation.endingpage5-
dc.citation.publicationnameMAGNETIC RESONANCE IN MEDICINE-
dc.identifier.doi10.1002/mrm.1910350102-
dc.contributor.localauthorRo, YongMan-
dc.contributor.nonIdAuthorCho, ZH-
dc.contributor.nonIdAuthorPark, ST-
dc.contributor.nonIdAuthorChung, SC-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorfunctional imaging-
dc.subject.keywordAuthortailored RF gradient echo (TRFGE) technique-
dc.subject.keywordAuthortrue susceptibility measurement-
dc.subject.keywordAuthorsusceptibility contrast enhancement in fMRI-
dc.subject.keywordPlusSENSORY STIMULATION-
dc.subject.keywordPlusMRI-
Appears in Collection
EE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 16 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0