For a Canada Deuterium Uranium 600 MWe (CANDU 6) reactor, a new power mapping method has been developed by using detector readings as boundary conditions. In this study, the measured detector readings are combined with the diffusion theory with the Kalman filtering (DIKAL) method. The measured detector readings are transformed into the measured mesh flux through appropriate approximation. And, the difference between calculated and measured mesh flux is filtered out by Kalman filtering technique. Then, the measured mesh fluxes are used as an internal boundary condition in the diffusion equation. The performance of the DIE;AL method has been assessed for the various core states, and has been also applied tr, the calculation of power and Aux distribution calculation in the CANDU 6 reactor. Sensitivity studies have shown that DIKAL is quite stable to the detector random and systematic errors. Also, it is shown that the DIKAL approach is more accurate than the currently used flux synthesis approach in CANDU 6 reactors.
Publisher
ATOMIC ENERGY SOC JAPAN
Issue Date
2000-09
Language
English
Article Type
Article
Citation

JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, v.37, no.9, pp.758 - 768

ISSN
0022-3131
URI
http://hdl.handle.net/10203/77262
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 7 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0