Superconducting pulse coil set for stability test of superconducting cables

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 351
  • Download : 0
A superconducting pulse coil set was constructed for transient stability experiment of CICC (Cable-In-Conduit Conductor). The pulse coil set was composed of an inner and an outer coil connected in series. With 5 T background field, the pulse coil produced an additional 2 T on the CICC. In order to simulate the TPX (Tokamak Physics Experiment) plasma initiation scenario, 2 T field drop from 7 T was tried with an approximate ramp rate of - 25 T/s. This paper describes the design for the pulse coil and presents the experimental results from its successful AC operation.
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Issue Date
1997-06
Language
English
Article Type
Article; Proceedings Paper
Keywords

CONDUCTORS

Citation

IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, v.7, no.2, pp.211 - 214

ISSN
1051-8223
DOI
10.1109/77.614469
URI
http://hdl.handle.net/10203/76432
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0