dc.description.abstractA differential-type amperometric biosensor based on conventional thick-film technology has been developed for breath alcohol measurement. The amperometric breath alcohol biosensor utilizes the alcohol dehydrogenase (ADH) and nicotinamide adenine dinucleotide (NAD(+)) cofactor which produce reduced NADH as a product of the oxidation of alcohol. The biosensor was designed in a differential format consisting of a common Ag/AgCl reference electrode, an active working electrode containing the ADH, and the inactive working electrode containing only bovine serum albumin instead of the ADH. The differential signal between the active working electrode and the inactive working electrode minimized the interference from a large number of oxidizable species present in a person's breath. Prior to the amperometric measurement the biosensor was hydrated simply by dipping it into a phosphate buffer solution at pH 7.4. The NADH produced from the enzymatic reaction was oxidized at the working electrode biased at a potential of 470 mV vs, an on-board Ag/AgCl reference electrode. The biosensor can measure a person's breath alcohol over the concentration range 20-800 ppm routinely required in a test of drunken driving. (C) 1999 Elsevier Science B.V. All rights reserved.-
dc.languageEnglish-
dc.publisherELSEVIER SCIENCE BV-
dc.subjectENZYME ELECTRODES-
dc.subjectHYDROGEN-PEROXIDE-
dc.subjectETHANOL VAPOR-
dc.subjectPHASE-
dc.subjectSENSORS-
dc.subjectSYSTEM-
dc.subjectSTABILIZATION-
dc.subjectOXIDASE-
dc.subjectLACTATE-
dc.subjectNADH-
dc.titleDetermination of breath alcohol using a differential-type amperometric biosensor based on alcohol dehydrogenase-
dc.typeArticle-
dc.identifier.wosid000080554900009-
dc.identifier.scopusid2-s2.0-0032919430-
dc.type.rimsART-
dc.citation.volume390-
dc.citation.issue1-3-
dc.citation.beginningpage83-
dc.citation.endingpage91-
dc.citation.publicationnameANALYTICA CHIMICA ACTA-
dc.identifier.doi10.1016/S0003-2670(99)00135-X-
dc.contributor.localauthorPark, Je-Kyun-
dc.contributor.nonIdAuthorYee, HJ-
dc.contributor.nonIdAuthorLee, KS-
dc.contributor.nonIdAuthorLee, WY-
dc.contributor.nonIdAuthorShin, MC-
dc.contributor.nonIdAuthorKim, TH-
dc.contributor.nonIdAuthorKim, SR-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorbiosensor-
dc.subject.keywordAuthorthick-film sensor-
dc.subject.keywordAuthoramperometric-
dc.subject.keywordAuthorbreath alcohol (ethanol)-
dc.subject.keywordAuthoralcohol dehydrogenase-
dc.subject.keywordPlusENZYME ELECTRODES-
dc.subject.keywordPlusHYDROGEN-PEROXIDE-
dc.subject.keywordPlusETHANOL VAPOR-
dc.subject.keywordPlusPHASE-
dc.subject.keywordPlusSENSORS-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlusSTABILIZATION-
dc.subject.keywordPlusOXIDASE-
dc.subject.keywordPlusLACTATE-
dc.subject.keywordPlusNADH-
Appears in Collection
BiS-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 92 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0