A Quantitative Evaluation of Chemical and Volume control System Design Simplification화학 및 체적 제어 계통 설계 단순화에 대한 정량적 평가에 관한 연구

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 339
  • Download : 0
One of the important features of the advanced nuclear power plants is the system simplification. In this work, a model has been introduced to quantitatively evaluate the system simplification. A few models have been developed for quantitative evaluation of design simplification and the design enhancements of CVCS of the advanced reactors have been evaluated with models based on the entropy concept and the system availability. In addition, operational interface of CVCS with peripheral systems has been considered to develop a new evaluation model in this work. The quantification results for the design of the System 80+ and KSNPP indicate that the simplicity of the CVCS is primarily dependent on the type and number of charging pumps.
Publisher
한국원자력학회
Issue Date
1995-10
Language
English
Citation

NUCLEAR ENGINEERING AND TECHNOLOGY , v.27, no.5, pp.753 - 759

ISSN
0372-7327
URI
http://hdl.handle.net/10203/68454
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0