AMORPHOUS-SILICON PIXEL LAYERS WITH CESIUM IODIDE CONVERTERS FOR MEDICAL RADIOGRAPHY

Cited 48 time in webofscience Cited 53 time in scopus
  • Hit : 582
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorJING, Tko
dc.contributor.authorGOODMAN, CAko
dc.contributor.authorDREWERY, Jko
dc.contributor.authorCho, Gyuseongko
dc.contributor.authorHONG, WSko
dc.contributor.authorLEE, Hko
dc.contributor.authorKAPLAN, SNko
dc.contributor.authorMIRESHGHI, Ako
dc.contributor.authorPEREZMENDEZ, Vko
dc.contributor.authorWILDERMUTH, Dko
dc.date.accessioned2013-02-27T07:06:08Z-
dc.date.available2013-02-27T07:06:08Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued1994-08-
dc.identifier.citationIEEE TRANSACTIONS ON NUCLEAR SCIENCE, v.41, no.4, pp.903 - 909-
dc.identifier.issn0018-9499-
dc.identifier.urihttp://hdl.handle.net/10203/67146-
dc.description.abstractWe describe the properties of evaporated layers of Cesium Iodide (Thallium activated) deposited on substrates that enable easy coupling to amorphous silicon pixel arrays. The CsI(Tl) layers range in thickness from 65 to 220mum. We used the two-boat evaporator system to deposit CsI(Tl) layers. This system ensures the formation of the scintillator film with homogenous thallium concentration which is essential for optimizing the scintillation light emission efficiency. The Tl concentration was kept to 0.1 -0.2 mole percent for the highest light output. Temperature annealing can affect the microstructure as well as light output of the CsI(Tl) film. 200-300-degrees-C temperature annealing can increase the light output by a factor of two. The amorphous silicon pixel arrays are p-in diodes approximately 1 mum thick with transparent electrodes to enable them to detect the scintillation light produced by X-rays incident on the CsI(Tl). Digital radiography requires a good spatial resolution. This is accomplished by making the detector pixel size less than 50mum. The light emission from the CsI(Tl) is collimated by techniques involving the deposition process on patterned substrates. We have measured MTF of greater than 12 line pairs per mm at the 10% level.-
dc.languageEnglish-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.subjectRADIATION-DAMAGE-
dc.subjectX-RAY-
dc.subjectCSI(TL) CRYSTALS-
dc.subjectCSI-
dc.subjectSCINTILLATORS-
dc.subjectDETECTORS-
dc.subjectREADOUT-
dc.subjectARRAYS-
dc.subjectYIELD-
dc.subjectCCD-
dc.titleAMORPHOUS-SILICON PIXEL LAYERS WITH CESIUM IODIDE CONVERTERS FOR MEDICAL RADIOGRAPHY-
dc.typeArticle-
dc.identifier.wosidA1994PE02800048-
dc.identifier.scopusid2-s2.0-0028493921-
dc.type.rimsART-
dc.citation.volume41-
dc.citation.issue4-
dc.citation.beginningpage903-
dc.citation.endingpage909-
dc.citation.publicationnameIEEE TRANSACTIONS ON NUCLEAR SCIENCE-
dc.identifier.doi10.1109/23.322829-
dc.contributor.localauthorCho, Gyuseong-
dc.contributor.nonIdAuthorJING, T-
dc.contributor.nonIdAuthorGOODMAN, CA-
dc.contributor.nonIdAuthorDREWERY, J-
dc.contributor.nonIdAuthorHONG, WS-
dc.contributor.nonIdAuthorLEE, H-
dc.contributor.nonIdAuthorKAPLAN, SN-
dc.contributor.nonIdAuthorMIRESHGHI, A-
dc.contributor.nonIdAuthorPEREZMENDEZ, V-
dc.contributor.nonIdAuthorWILDERMUTH, D-
dc.type.journalArticleArticle; Proceedings Paper-
dc.subject.keywordPlusRADIATION-DAMAGE-
dc.subject.keywordPlusX-RAY-
dc.subject.keywordPlusCSI(TL) CRYSTALS-
dc.subject.keywordPlusCSI-
dc.subject.keywordPlusSCINTILLATORS-
dc.subject.keywordPlusDETECTORS-
dc.subject.keywordPlusREADOUT-
dc.subject.keywordPlusARRAYS-
dc.subject.keywordPlusYIELD-
dc.subject.keywordPlusCCD-
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 48 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0