Nonlinear stability domain analysis of a CANDU reactor캔두형 원자로 노심의 비선형 안정영역 해석

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 422
  • Download : 0
DC FieldValueLanguage
dc.contributor.advisorCho, Nam-Zin-
dc.contributor.advisor조남진-
dc.contributor.authorLee, Kyong-Baek-
dc.contributor.author이경백-
dc.date.accessioned2011-12-14T08:13:46Z-
dc.date.available2011-12-14T08:13:46Z-
dc.date.issued1993-
dc.identifier.urihttp://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=68453&flag=dissertation-
dc.identifier.urihttp://hdl.handle.net/10203/49285-
dc.description학위논문(석사) - 한국과학기술원 : 원자력공학과, 1993.2, [ viii, 62 p. ]-
dc.description.abstractThe asymptotic stability domain of a CANDU reactor was estimated for the various values of feedback and design parameters utilizing the expansion method. The expansion method for identifying nonlinear stability domain requires only a positive definite function and it is particularly useful for stiff systems such as a nuclear reactor. From a large starting region, the entire stability domain is estimated effectively after sufficient iterations. The dynamic equations for a CANDU reactor with four reactivity feedbacks are developed from the relation of energy balance and nonlinear analysis is performed for the steady-state solution. By analysis of bifucation theory, nonlinear phenomena are observed for various distributions of reactivity feedback coefficients. Hopf bifurcation point are situated on the dynamic stability boundary and stable limit cycles and unstable limit cycles of the steady-state solutions exist for certain values of the reactivity coefficients. We observed that feedback and design parameters change the size of the stability domain. In a CANDU reactor, the stability is determined chiefly by the extent of void at saturated state of coolant. It is noteworthy that the stability domain is scarcely affected by the moderator temperature coefficient. The stability domain increases as the fuel temperature coefficient decreases (in negative values) and the coolant temperature coefficient decreases (in positive values). As the mass flow rate of the coolant increases, the stability domain becomes large, and as the reactor power increases, the stability domain becomes small.eng
dc.languageeng-
dc.publisher한국과학기술원-
dc.titleNonlinear stability domain analysis of a CANDU reactor-
dc.title.alternative캔두형 원자로 노심의 비선형 안정영역 해석-
dc.typeThesis(Master)-
dc.identifier.CNRN68453/325007-
dc.description.department한국과학기술원 : 원자력공학과, -
dc.identifier.uid000911398-
dc.contributor.localauthorLee, Kyong-Baek-
dc.contributor.localauthor이경백-
Appears in Collection
NE-Theses_Master(석사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley