(A) theoretical study for the real-time assessment of external gamma exposure using equivalent-volume numerical integration등적 수치적분을 이용한 외부 감마피폭의 실시간평가를 위한 이론적연구

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 460
  • Download : 0
DC FieldValueLanguage
dc.contributor.advisorChun, Moon-Hyun-
dc.contributor.advisor전문헌-
dc.contributor.authorHan, Moon-Hee-
dc.contributor.author한문희-
dc.date.accessioned2011-12-14T08:03:22Z-
dc.date.available2011-12-14T08:03:22Z-
dc.date.issued1995-
dc.identifier.urihttp://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=98817&flag=dissertation-
dc.identifier.urihttp://hdl.handle.net/10203/48832-
dc.description학위논문(박사) - 한국과학기술원 : 원자력공학과, 1995.2, [ xii, 147 p. ]-
dc.description.abstractAn approximate method for estimating gamma external dose due to an arbitrary distribution of radioactive material has been developed. For the assessment of external gamma dose, the space over which radioactive material is distributed has been assumed to be composed of hexagonal cells. The evaluation of three-dimensional integration over the space is an extremely time-consuming task. Hence, a different approach has been used for the study, i.e., a equivalent-volume spherical approach in which a regular hexahedron is modeled as a equivalent-volume sphere to simplify the integration. For the justification of the current approach, two case studies have been performed: a comparison with a point source approximation and a comparison of external dose rate with the Monte Carlo integration. These comparisons show that the current approach gives reasonable results in a physical sense. Computing times of the developed and Monte Carlo integration method on VAX system have been compared as a function of the number of hexagonal cells. This comparison shows that CPU times for both methods are comparable in the region of small number of cells, but in the region of large number, Monte Carlo integration needs much more computing times. The proposed method is shown to have an accuracy equivalent to Monte Carlo method with an advantage of much shorter calculation time. Then, the method developed here evaluates early off-site consequences of a nuclear accident. An accident consequence assessment model has been integrated using Gaussian puff model which is used to obtain the distribution of radioactive material in the air and on the ground. For this work, the real meteorological data measured at Kori site for 10 years (1976 - 1985) have been statistically analyzed for obtaining site-specific conditions. The short-term external gamma exposures have been assessed for several site-specific meteorological conditions. The results show that the extent and the pattern of short-term externa...eng
dc.languageeng-
dc.publisher한국과학기술원-
dc.title(A) theoretical study for the real-time assessment of external gamma exposure using equivalent-volume numerical integration-
dc.title.alternative등적 수치적분을 이용한 외부 감마피폭의 실시간평가를 위한 이론적연구-
dc.typeThesis(Ph.D)-
dc.identifier.CNRN98817/325007-
dc.description.department한국과학기술원 : 원자력공학과, -
dc.identifier.uid000835659-
dc.contributor.localauthorHan, Moon-Hee-
dc.contributor.localauthor한문희-