DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Park, Hyun-Wook | - |
dc.contributor.advisor | 박현욱 | - |
dc.contributor.author | Yun, Sung-Dae | - |
dc.contributor.author | 윤성대 | - |
dc.date.accessioned | 2011-12-14 | - |
dc.date.available | 2011-12-14 | - |
dc.date.issued | 2009 | - |
dc.identifier.uri | http://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=327774&flag=dissertation | - |
dc.identifier.uri | http://hdl.handle.net/10203/35541 | - |
dc.description | 학위논문(박사) - 한국과학기술원 : 전기및전자공학전공, 2009. 8., [ ix, 102 p. ] | - |
dc.description.abstract | Echo-planar imaging (EPI) techniques have generally been used for fMRI studies due to their fast imaging time. However, it is difficult for studying brain function at the submilliter level using this sequence. In addition, EPI techniques have some drawbacks, such as Nyquist ghosts and geometric distortions in the reconstructed images, and subsequently require additional post-processing to reduce these artifacts. One way of solving these problems is to acquire fMRI data by means of a conventional gradient-echo imaging sequence instead of EPI. To provide a fast imaging time, the proposed method combines higher-order generalized series (HGS) imaging with a parallel imaging technique which is called the HGS-parallel technique. The proposed HGS-parallel technique achieves a 12.8-fold acceleration in imaging time without the cost of spatial resolution. The proposed method was verified through the application of fMRI studies on normal subjects. This study suggests that the proposed method can be used for high-resolution fMRI studies without the geometric distortion and the Nyquist ghost artifacts compared to EPI. | eng |
dc.language | eng | - |
dc.publisher | 한국과학기술원 | - |
dc.subject | echo-planar imaging (EPI) | - |
dc.subject | functional MRI (fMRI) | - |
dc.subject | higher-order generalized series imaging | - |
dc.subject | high spatial resolution MRI | - |
dc.subject | parallel imaging | - |
dc.subject | 에코 평면 영상법 | - |
dc.subject | 기능 자기공명영상법 | - |
dc.subject | 고차 일반 급수 영상법 | - |
dc.subject | 고해상도 자기공명영상 | - |
dc.subject | 병렬 영상법 | - |
dc.subject | echo-planar imaging (EPI) | - |
dc.subject | functional MRI (fMRI) | - |
dc.subject | higher-order generalized series imaging | - |
dc.subject | high spatial resolution MRI | - |
dc.subject | parallel imaging | - |
dc.subject | 에코 평면 영상법 | - |
dc.subject | 기능 자기공명영상법 | - |
dc.subject | 고차 일반 급수 영상법 | - |
dc.subject | 고해상도 자기공명영상 | - |
dc.subject | 병렬 영상법 | - |
dc.title | (A) high-resolution MR imaging method using HGS (Higher-Order Generalized Series)-parallel technique and its application to fMRI | - |
dc.title.alternative | 고차 일반 급수와 병렬 영상법을 이용한 고해상도 자기공명영상법 및 뇌기능 영상에의 응용 | - |
dc.type | Thesis(Ph.D) | - |
dc.identifier.CNRN | 327774/325007 | - |
dc.description.department | 한국과학기술원 : 전기및전자공학전공, | - |
dc.identifier.uid | 020045856 | - |
dc.contributor.localauthor | Park, Hyun-Wook | - |
dc.contributor.localauthor | 박현욱 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.