T2 prime mapping from highly undersampled data using compressed sensing with patch based low rank penalty

Cited 2 time in webofscience Cited 0 time in scopus
  • Hit : 57
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorLee, Dongwookko
dc.contributor.authorKim, Eung Yeopko
dc.contributor.authorYoon, Huisuko
dc.contributor.authorPark, Sung-Hongko
dc.contributor.authorYe, Jong Chulko
dc.date.accessioned2023-11-01T07:00:28Z-
dc.date.available2023-11-01T07:00:28Z-
dc.date.created2023-11-01-
dc.date.issued2014-04-
dc.identifier.citation2014 IEEE 11th International Symposium on Biomedical Imaging, ISBI 2014, pp.645 - 648-
dc.identifier.issn1945-7928-
dc.identifier.urihttp://hdl.handle.net/10203/314012-
dc.description.abstractIn magnetic resonance (MR) imaging, T2 and T2 star (T2∗) relaxation times represent tissue properties, which can be quantified by specific imaging sequences. Especially, T2 prime (T2′) that can be derived from T2 and T2∗ are clinically valuable for delineation of areas with increased oxygen extraction fraction in acute stroke. However, there are limitations in this method because it requires acquisition of many images for the generation of T2 and T2∗ relaxation time maps. In particular, time saving is the most important factor in acquisition of MRI in acute ischemic stroke because therapy should be given to patients as soon as possible. Therefore, to reduce the acquisition time of MR data, we use a compressed sensing algorithm using patch based low rank penalty for the reconstruction of T2 and T2∗ weighted images to obtain the T2 prime map. Our results showed that significant acceleration in T2′ image acquisition is possible using the proposed method.-
dc.languageEnglish-
dc.publisherInstitute of Electrical and Electronics Engineers Inc.-
dc.titleT2 prime mapping from highly undersampled data using compressed sensing with patch based low rank penalty-
dc.typeConference-
dc.identifier.wosid000392750900160-
dc.identifier.scopusid2-s2.0-84927940118-
dc.type.rimsCONF-
dc.citation.beginningpage645-
dc.citation.endingpage648-
dc.citation.publicationname2014 IEEE 11th International Symposium on Biomedical Imaging, ISBI 2014-
dc.identifier.conferencecountryCC-
dc.identifier.conferencelocationBeijing-
dc.identifier.doi10.1109/isbi.2014.6867953-
dc.contributor.localauthorPark, Sung-Hong-
dc.contributor.localauthorYe, Jong Chul-
dc.contributor.nonIdAuthorKim, Eung Yeop-
Appears in Collection
BiS-Conference Papers(학술회의논문)AI-Conference Papers(학술대회논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 2 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0