소형 고온 아크-제트 풍동 장비 구축 및 초기 성능 평가에 관한 연구A Study on the Configuration and Initial Performance Evaluation of Small-Scaled High-Temperature Arc-Jet Wind Tunnel Facility

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 91
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorChoi, Ilsungko
dc.contributor.authorYang, Sungmoko
dc.contributor.authorShin, Donghako
dc.contributor.authorLee, Hyunsukko
dc.contributor.authorPark, Sanghako
dc.contributor.authorPARK, GISUko
dc.date.accessioned2023-10-25T02:00:21Z-
dc.date.available2023-10-25T02:00:21Z-
dc.date.created2023-09-04-
dc.date.created2023-09-04-
dc.date.created2023-09-04-
dc.date.created2023-09-04-
dc.date.created2023-09-04-
dc.date.created2023-09-04-
dc.date.created2023-09-04-
dc.date.created2023-09-04-
dc.date.created2023-09-04-
dc.date.issued2023-10-
dc.identifier.citation한국항공우주학회지, v.51, no.10, pp.677 - 684-
dc.identifier.issn1225-1348-
dc.identifier.urihttp://hdl.handle.net/10203/313782-
dc.description.abstractThe present study built a small-scaled, high-temperature arc-jet wind tunnel facility (30 kW-class) for thermal protection system evaluation. Flow properties were measured and estimated to evaluate the facility’s performance. The constructed facility utilizes a Huels-type arc generator with a supersonic nozzle with an exit diameter of 28 mm. The facility’s performance evaluation was performed at the 1.03 g/s of supplied test gas’s mass flow rate and 85 A of input current. An arc column pressure, a pitot pressure, and a stagnation heat flux are measured using cylinder-shaped probes with a diameter of 10 mm, and they were 32.6 kPa, 4.39 kPa, and 1.99 MW/m2, respectively. Based on the measurements, the mass-averaged and centerline enthalpies were estimated as 3.22 MJ/kg and 10.9 MJ/kg, respectively, and the estimated static pressure, temperature, and Mach number at the nozzle exit were 250 Pa, 920 K, and 3.7, respectively. The estimated parameters were compared with large-scaled arc-jet wind tunnel facilities, showing that the present small-scaled facility could simulate a portion of large-scaled facilities’ operational envelope.-
dc.languageKorean-
dc.publisher한국항공우주학회-
dc.title소형 고온 아크-제트 풍동 장비 구축 및 초기 성능 평가에 관한 연구-
dc.title.alternativeA Study on the Configuration and Initial Performance Evaluation of Small-Scaled High-Temperature Arc-Jet Wind Tunnel Facility-
dc.typeArticle-
dc.identifier.wosid001125490200002-
dc.identifier.scopusid2-s2.0-85175304718-
dc.type.rimsART-
dc.citation.volume51-
dc.citation.issue10-
dc.citation.beginningpage677-
dc.citation.endingpage684-
dc.citation.publicationname한국항공우주학회지-
dc.identifier.doi10.5139/JKSAS.2023.51.10.677-
dc.identifier.kciidART003003622-
dc.contributor.localauthorPARK, GISU-
dc.contributor.nonIdAuthorShin, Dongha-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorArc-Jet Wind Tunnel-
dc.subject.keywordAuthorCompressible Flow-
dc.subject.keywordAuthorPerformance Evaluation-
dc.subject.keywordAuthorAerothermo-dynamics-
Appears in Collection
AE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0