Pixel-Grouping G(E) Functions for Estimating Dose Rates from Unknown Source Distributions with a Position-Sensitive Detector

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 99
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorKim, Hojikko
dc.contributor.authorKim, Junhyeokko
dc.contributor.authorHwang, Jisungko
dc.contributor.authorKo, Kilyoungko
dc.contributor.authorCho, Gyuseongko
dc.date.accessioned2023-06-21T03:00:20Z-
dc.date.available2023-06-21T03:00:20Z-
dc.date.created2023-06-21-
dc.date.created2023-06-21-
dc.date.issued2023-05-
dc.identifier.citationSENSORS, v.23, no.10-
dc.identifier.issn1424-8220-
dc.identifier.urihttp://hdl.handle.net/10203/307378-
dc.description.abstractEstimating accurate radiation doses when a radioactive source's location is unknown can protect workers from radiation exposure. Unfortunately, depending on a detector's shape and directional response variations, conventional G(E) function can be prone to inaccurate dose estimations. Therefore, this study estimated accurate radiation doses regardless of source distributions, using the multiple G(E) function groups (i.e., pixel-grouping G(E) functions) within a position-sensitive detector (PSD), which records the response position and energy inside the detector. Investigations revealed that, compared with the conventional G(E) function when source distributions are unknown, this study's proposed pixel-grouping G(E) functions improved dose estimation accuracy by more than 1.5 times. Furthermore, although the conventional G(E) function produced substantially larger errors in certain directions or energy ranges, the proposed pixel-grouping G(E) functions estimate doses with more uniform errors at all directions and energies. Therefore, the proposed method estimates the dose with high accuracy and provides reliable results regardless of the location and energy of the source.-
dc.languageEnglish-
dc.publisherMDPI-
dc.titlePixel-Grouping G(E) Functions for Estimating Dose Rates from Unknown Source Distributions with a Position-Sensitive Detector-
dc.typeArticle-
dc.identifier.wosid000996701600001-
dc.identifier.scopusid2-s2.0-85160403715-
dc.type.rimsART-
dc.citation.volume23-
dc.citation.issue10-
dc.citation.publicationnameSENSORS-
dc.identifier.doi10.3390/s23104591-
dc.contributor.localauthorCho, Gyuseong-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorG(E) function-
dc.subject.keywordAuthorspectrum-to-dose conversion coefficient-
dc.subject.keywordAuthorposition sensitive detector (PSD)-
dc.subject.keywordAuthorcadmium zinc telluride (CZT)-
dc.subject.keywordAuthorambient dose equivalent-
dc.subject.keywordPlusSPECTRA-
dc.subject.keywordPlusNAI(TL)-
dc.subject.keywordPlusSYSTEM-