A modified decaying source method for dead time measurement with non-negligible background counts

Cited 1 time in webofscience Cited 0 time in scopus
  • Hit : 89
  • Download : 0
This study aims to propose a modified decaying source method for dead time measurement with non-negligible background counts. A radiation portal monitor (RPM) system with 173 x 28.4 x 6.4 cm3 sized PVT scintillation detectors was used for the experiment. For each source, various activities were measured to evaluate counting losses due to the dead time, and three types of sources were considered to validate the energy dependency of the dead time. The results showed that the evaluated true count rate based on the nonparalyzable dead time model is in good agreement with the experimental data and the dead time increases when the energy of the incident radiation decreases. The proposed method is expected to be used for dead time measurement of radiation detection systems with non-negligible background counts.
Publisher
ELSEVIER
Issue Date
2023-03
Language
English
Article Type
Article
Citation

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, v.1048

ISSN
0168-9002
DOI
10.1016/j.nima.2023.168026
URI
http://hdl.handle.net/10203/306989
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 1 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0