Low power bio-impedance sensor IC with precise phase measurement정확한 위상 측정이 가능한 저전력 생체임피던스 센서 회로

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 323
  • Download : 0
Continuous monitoring of fluid status through bio-impedance (Bio-Z) measurement of thoracic magnitude or phase is critical in reducing the mortality of chronic heart failure (CHF) patients. However, the stringent power constraints of implantable devices force the design of Bio-Z sensors to be highly challenging. In this dissertation, two low-voltage and low-power ICs are proposed for bio-impedance (Bio-Z) sensing applications, both of which are fabricated in a 65 nm CMOS process. The first IC features a sub-10-μW power consumption operating from a 0.5 V supply, sustaining a sub-1º of phase error even under 10% of supply and 0ºC–70ºC of temperature variations. It exhibits a 15.28 mΩ/√Hz of input-referred impedance noise performance, occupying a 4.83 mm² of active area. Its linearity performance shows that the magnitude and the phase of Bio-Z can be measured within the error of 2% and 0.4º, respectively, given that the magnitude of load impedance is less than 126 Ω, and thus, it is suitable for fluid status monitoring applications. Experimental measurement on the human chest demonstrates its capabilities of thoracic impedance variance (TIV) and impedance cardiography (ICG) monitoring. The second IC features a sub-10-μW and a sub-0.1% THD sinusoidal current generator (CG) that is capable of 20 kHz output current driving. This IC also operates from a 0.5 V supply, benefiting from the ultra-low-power nature of near-threshold operation of digital circuit. With a 2 μApp amplitude of sinusoidal current, it assures <1% of driving error up to the load impedance of 2 kΩ, occupying a 0.059mm² of active area.
Advisors
Yoo, Hoi-Junresearcher유회준researcher
Description
한국과학기술원 :전기및전자공학부,
Publisher
한국과학기술원
Issue Date
2021
Identifier
325007
Language
eng
Description

학위논문(박사) - 한국과학기술원 : 전기및전자공학부, 2021.2,[iv, 83 p. :]

Keywords

Bio-Impedance(Bio-Z)▼achronic heart failure(CHF)▼aheart rate(HR)▼aImpedance Cardiography(ICG)▼aImplantable Device▼aInput Referred Impedance Noise▼aleft-ventricular ejection time(LVET)▼alow Supply▼aphase▼athoracic impedance variance(TIV); 생체 임피던스▼a만성 심부전▼a심박수▼a임피던스 심박동 기록법▼a이식형 장치▼a입력기준 임피던스 잡음▼a좌심실박출시간▼a저전압▼a위상▼a흉부 임피던스 변동량

URI
http://hdl.handle.net/10203/295674
Link
http://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=956664&flag=dissertation
Appears in Collection
EE-Theses_Ph.D.(박사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0