Spread spectrum surface plasmon resonance sensor for ultrasensitive detection of E.coli O157:H7 using dual LED excitation초 민감 대장균 검출을 위한 이중 발광 다이오드 기반 확산 스펙트럼 표면 플라즈몬 공명 센서

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 301
  • Download : 0
DC FieldValueLanguage
dc.contributor.advisorJeong, Ki-Hun-
dc.contributor.advisor정기훈-
dc.contributor.authorKim, Gi-Beom-
dc.date.accessioned2021-05-13T19:37:03Z-
dc.date.available2021-05-13T19:37:03Z-
dc.date.issued2020-
dc.identifier.urihttp://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=925086&flag=dissertationen_US
dc.identifier.urihttp://hdl.handle.net/10203/284927-
dc.description학위논문(석사) - 한국과학기술원 : 바이오및뇌공학과, 2020.8,[x, 62 p. :]-
dc.description.abstractWater quality monitoring is the primary control point in the prevention of disease caused by pathogens Especially, Escherichia Coli (E.coli) is known as fecal indicator bacteria. E.coli detection is important because water quality can be easily determined. However, Conventional water monitoring methods to detect E.coli are time consuming and laboratory-based assay. Therefore, simple and fast detection method is needed. Surface plasmon resonance (SPR) are getting attention in optical bio-sensing applications because it has many advantages that label free, without various agents, minimal amount sample and real-time monitoring. The most widespread mode of SPR sensor is Kretschmann geometry. This configuration is bulky and has limitation for increasing resolution due to various noises. We proposed compact spread spectrum SPR (ss-SPR) sensor with high signal-to-noise-ratio (SNR) using dual wavelengths LED appling spread spectrum technique. The compact ss-SPR sensor was designed to be 27mm width and 37mm height size. Standard deviation measured by spread spectrum technique was 35 percentage decreased and SNR was increased about 100 times than continuous wave (CW) measurement. And limit of detection (LOD) of e.coli was $2.24 \times 10^2cfu/ml$, which is an improvement over the result of CW measurement. The proposed compact ss-SPR sensor will be applied for low concentration target molecule detection.-
dc.languageeng-
dc.publisher한국과학기술원-
dc.subjectSurface plasmon resonance sensor▼acompact▼aspread spectrum technique▼aE.coli▼aLimit of detection-
dc.subject표면 플라즈몬 공명 센서▼a소형▼a화산 스팩트럼 기술▼a대장균▼a검출한계-
dc.titleSpread spectrum surface plasmon resonance sensor for ultrasensitive detection of E.coli O157:H7 using dual LED excitation-
dc.title.alternative초 민감 대장균 검출을 위한 이중 발광 다이오드 기반 확산 스펙트럼 표면 플라즈몬 공명 센서-
dc.typeThesis(Master)-
dc.identifier.CNRN325007-
dc.description.department한국과학기술원 :바이오및뇌공학과,-
dc.contributor.alternativeauthor김기범-
Appears in Collection
BiS-Theses_Master(석사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0