Wireless, soft electronics for rapid, multisensor measurements of hydration levels in healthy and diseased skin

Cited 30 time in webofscience Cited 22 time in scopus
  • Hit : 502
  • Download : 168
DC FieldValueLanguage
dc.contributor.authorKwon, Kyeonghako
dc.contributor.authorWang, Helingko
dc.contributor.authorLim, Jaemanko
dc.contributor.authorChun, Keum Sanko
dc.contributor.authorJang, Hokyungko
dc.contributor.authorYoo, Injaeko
dc.contributor.authorWu, Derekko
dc.contributor.authorChen, Alyssa Jieko
dc.contributor.authorGu, Carol Geko
dc.contributor.authorLipschultz, Lindsayko
dc.contributor.authorKim, Jong Ukko
dc.contributor.authorKim, Jihyeko
dc.contributor.authorJeong, Hyoyoungko
dc.contributor.authorLuan, Haiwenko
dc.contributor.authorPark, Yoonseokko
dc.contributor.authorSu, Chun-Juko
dc.contributor.authorIshida, Yuiko
dc.contributor.authorMadhvapathy, Surabhi R.ko
dc.contributor.authorIkoma, Akihikoko
dc.contributor.authorKwak, Jean Wonko
dc.contributor.authorYang, Somko
dc.contributor.authorBanks, Anthonyko
dc.contributor.authorXu, Shuaiko
dc.contributor.authorHuang, Yonggangko
dc.contributor.authorChang, Jan-Kaiko
dc.contributor.authorRogers, John A.ko
dc.date.accessioned2021-02-05T04:50:06Z-
dc.date.available2021-02-05T04:50:06Z-
dc.date.created2021-02-04-
dc.date.created2021-02-04-
dc.date.created2021-02-04-
dc.date.created2021-02-04-
dc.date.created2021-02-04-
dc.date.issued2021-01-
dc.identifier.citationPROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, v.118, no.5, pp.e202039811-
dc.identifier.issn0027-8424-
dc.identifier.urihttp://hdl.handle.net/10203/280598-
dc.description.abstract<jats:p>Precise, quantitative measurements of the hydration status of skin can yield important insights into dermatological health and skin structure and function, with additional relevance to essential processes of thermoregulation and other features of basic physiology. Existing tools for determining skin water content exploit surrogate electrical assessments performed with bulky, rigid, and expensive instruments that are difficult to use in a repeatable manner. Recent alternatives exploit thermal measurements using soft wireless devices that adhere gently and noninvasively to the surface of the skin, but with limited operating range (∼1 cm) and high sensitivity to subtle environmental fluctuations. This paper introduces a set of ideas and technologies that overcome these drawbacks to enable high-speed, robust, long-range automated measurements of thermal transport properties via a miniaturized, multisensor module controlled by a long-range (∼10 m) Bluetooth Low Energy system on a chip, with a graphical user interface to standard smartphones. Soft contact to the surface of the skin, with almost zero user burden, yields recordings that can be quantitatively connected to hydration levels of both the epidermis and dermis, using computational modeling techniques, with high levels of repeatability and insensitivity to ambient fluctuations in temperature. Systematic studies of polymers in layered configurations similar to those of human skin, of porcine skin with known levels of hydration, and of human subjects with benchmarks against clinical devices validate the measurement approach and associated sensor hardware. The results support capabilities in characterizing skin barrier function, assessing severity of skin diseases, and evaluating cosmetic and medication efficacy, for use in the clinic or in the home.</jats:p>-
dc.languageEnglish-
dc.publisherNATL ACAD SCIENCES-
dc.titleWireless, soft electronics for rapid, multisensor measurements of hydration levels in healthy and diseased skin-
dc.typeArticle-
dc.identifier.wosid000615345200040-
dc.identifier.scopusid2-s2.0-85100015794-
dc.type.rimsART-
dc.citation.volume118-
dc.citation.issue5-
dc.citation.beginningpagee202039811-
dc.citation.publicationnamePROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-
dc.identifier.doi10.1073/pnas.2020398118-
dc.contributor.localauthorKwon, Kyeongha-
dc.contributor.nonIdAuthorWang, Heling-
dc.contributor.nonIdAuthorLim, Jaeman-
dc.contributor.nonIdAuthorChun, Keum San-
dc.contributor.nonIdAuthorJang, Hokyung-
dc.contributor.nonIdAuthorWu, Derek-
dc.contributor.nonIdAuthorChen, Alyssa Jie-
dc.contributor.nonIdAuthorGu, Carol Ge-
dc.contributor.nonIdAuthorLipschultz, Lindsay-
dc.contributor.nonIdAuthorKim, Jong Uk-
dc.contributor.nonIdAuthorKim, Jihye-
dc.contributor.nonIdAuthorJeong, Hyoyoung-
dc.contributor.nonIdAuthorLuan, Haiwen-
dc.contributor.nonIdAuthorPark, Yoonseok-
dc.contributor.nonIdAuthorSu, Chun-Ju-
dc.contributor.nonIdAuthorIshida, Yui-
dc.contributor.nonIdAuthorMadhvapathy, Surabhi R.-
dc.contributor.nonIdAuthorIkoma, Akihiko-
dc.contributor.nonIdAuthorKwak, Jean Won-
dc.contributor.nonIdAuthorYang, Som-
dc.contributor.nonIdAuthorBanks, Anthony-
dc.contributor.nonIdAuthorXu, Shuai-
dc.contributor.nonIdAuthorHuang, Yonggang-
dc.contributor.nonIdAuthorChang, Jan-Kai-
dc.contributor.nonIdAuthorRogers, John A.-
dc.description.isOpenAccessY-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorBiomedical devices-
dc.subject.keywordAuthorDiagnostics-
dc.subject.keywordAuthorFlexible electronics-
dc.subject.keywordAuthorHealth monitoring-
dc.subject.keywordAuthorWireless electronics-
Appears in Collection
EE-Journal Papers(저널논문)
Files in This Item
118186.pdf(1.96 MB)Download
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 30 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0