Development of the screen-printed multi-biosensor for amperometric determination of LDH, ALT and AST levels in biological fluids스크린 프린팅 기술을 이용한 LDH, ALT 및 AST 측정용 후막형 전기화학식 멀티 바이오센서의 개발

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 854
  • Download : 0
DC FieldValueLanguage
dc.contributor.advisorKim, Hak-Sung-
dc.contributor.advisor김학성-
dc.contributor.authorChang, Je-Young-
dc.contributor.author장제영-
dc.date.accessioned2011-12-12T08:52:11Z-
dc.date.available2011-12-12T08:52:11Z-
dc.date.issued2000-
dc.identifier.urihttp://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=158711&flag=dissertation-
dc.identifier.urihttp://hdl.handle.net/10203/27911-
dc.description학위논문(석사) - 한국과학기술원 : 생물과학과, 2000.2, [ v, 54 p. ]-
dc.description.abstractThe screen-printed multi-biosensors for amperometric determination of LDH, ALT and AST levels in biological fluids have been constructed on the basis of $NAD^+$/NADH-dependent dehydrogenase reaction. The printing ink used for the fabrication of working electrode where enzyme-catalyzed reaction takes place is composed of reagents for enzyme reaction, polymer binder, 3,4-dihydroxybenzaldehyde (3,4-DHB) as electron-transfer mediator and graphite particle as conducting material. The printing-step is followed by electrodeposition of 3,4-DHB by potential cycling from -200 mV to +300 mV vs. standard Ag/AgCl reference electrode. Voltammetric and amperometric studies show that the multi-biosensor modified with 3,4-DHB could efficiently catalyze electrochemical oxidation of NADH generated by enzyme reaction, which indicate that electrode fouling due to direct electrochemical oxidation of NADH can be bypassed through this approach. Optimal conditions for the electrochemical determination of LDH, ALT and AST have been also investigated in terms of sensitivity. The calibration curve of the multi-biosensor for LDH level exhibits linear range up to 500 U/L and the detection limit is 50 U/L. In cases of the electrochemical determination of ALT and AST levels, both calibration curves of the multi- biosensor show linear range up to 600 U/L and the detection limits are 10 U/L in common.eng
dc.languageeng-
dc.publisher한국과학기술원-
dc.subjectAlanine aminotransferase (ALT)-
dc.subjectLactate dehydrogenase (LDH)-
dc.subjectScreen-printing technology-
dc.subjectAmperometric biosensor-
dc.subjectAspartate aminotransferase (AST)-
dc.subject아스파테이트 아미노기 전이효소-
dc.subject알라닌 아미노기 전이효소-
dc.subject젖산 탈수소 효소-
dc.subject스크린 프린팅 기술-
dc.subject전기화학식 바이오센서-
dc.titleDevelopment of the screen-printed multi-biosensor for amperometric determination of LDH, ALT and AST levels in biological fluids-
dc.title.alternative스크린 프린팅 기술을 이용한 LDH, ALT 및 AST 측정용 후막형 전기화학식 멀티 바이오센서의 개발-
dc.typeThesis(Master)-
dc.identifier.CNRN158711/325007-
dc.description.department한국과학기술원 : 생물과학과, -
dc.identifier.uid000983503-
dc.contributor.localauthorKim, Hak-Sung-
dc.contributor.localauthor김학성-
Appears in Collection
BS-Theses_Master(석사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike