A locally segmented reconstruction method for parallel imaging

Cited 1 time in webofscience Cited 0 time in scopus
  • Hit : 393
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorSo, Seoheeko
dc.contributor.authorSeo, Hyunseokko
dc.contributor.authorPark, HyunWookko
dc.date.accessioned2020-11-10T07:55:09Z-
dc.date.available2020-11-10T07:55:09Z-
dc.date.created2020-03-12-
dc.date.created2020-03-12-
dc.date.issued2020-09-
dc.identifier.citationMAGNETIC RESONANCE IN MEDICINE, v.84, no.3, pp.1638 - 1647-
dc.identifier.issn0740-3194-
dc.identifier.urihttp://hdl.handle.net/10203/277186-
dc.description.abstractPurpose A locally segmented parallel imaging reconstruction method is proposed that efficiently utilizes sensitivity distribution of multichannel receiver coil. Theory and Methods A method of locally segmenting a MR signal is introduced to maximize the differences in sensitivity between receiver channels. A 1D Fourier transformation of the undersampled k-space data is performed along the readout direction, which generates a hybrid 2D space. The hybrid space is partitioned into localized segments along the readout direction. In every localized segment, kernels representing relation between adjacent signals are estimated from autocalibration signals, and data at unsampled points are estimated using the kernels. Then, the images are reconstructed from full k-space data that consists of the sampled data and the estimated data at unsampled points. Results In a computer simulation and in vivo experiments, the locally segmented reconstruction method produced fewer residual artifacts compared to the conventional parallel imaging reconstruction methods with the same kernel geometry. The performance gain of the proposed method comes from maximizing encoding capability of receiver channels, thus resulting in the accurately estimated kernel weights that reflect the relation between adjacent signals. Conclusion The proposed spatial segmentation method maximally utilizes differences in the sensitivity of receiver channels to reconstruct images with reduced artifacts.-
dc.languageEnglish-
dc.publisherWILEY-
dc.titleA locally segmented reconstruction method for parallel imaging-
dc.typeArticle-
dc.identifier.wosid000514107800001-
dc.identifier.scopusid2-s2.0-85079733156-
dc.type.rimsART-
dc.citation.volume84-
dc.citation.issue3-
dc.citation.beginningpage1638-
dc.citation.endingpage1647-
dc.citation.publicationnameMAGNETIC RESONANCE IN MEDICINE-
dc.identifier.doi10.1002/mrm.28193-
dc.contributor.localauthorPark, HyunWook-
dc.contributor.nonIdAuthorSeo, Hyunseok-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthoraliasing artifacts-
dc.subject.keywordAuthorlocally segmented reconstruction-
dc.subject.keywordAuthormultichannel receiver coil-
dc.subject.keywordAuthorparallel imaging-
dc.subject.keywordPlusRADIOFREQUENCY COIL-
dc.subject.keywordPlusAUTO-SMASH-
Appears in Collection
EE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 1 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0