Assessment of Renal Perfusion in Transplanted Kidney Patients Using Pseudo-Continuous Arterial Spin Labeling with Multiple Post-Labeling Delays

Cited 12 time in webofscience Cited 8 time in scopus
  • Hit : 352
  • Download : 0
Purpose: To investigate technical issues for implementing pseudo-continuous arterial spin labeling (pCASL) for renal perfusion measurements in transplanted kidney patients (TK) in the early postoperative recovery phase. Methods: Eleven subjects were scanned: TK (N= 4, 42 +/- 8.1Y) and normal volunteers (NV) (N= 7, 25 +/- 3Y). In 3.0 T clinical MRI, pCASL with a 2D balanced steady-state free precession readout was applied with four different post-labeling delays: 0.5/1.0/1.5/2.0 s. Perfusion images were acquired with and without background suppression and processed with and without registration for comparison. Renal blood flow (RBF) and arterial transit time (ATT) values were calculated from each pixel of images. The F-test, Wilcoxon signed-rank test, and Wilcoxon rank-sum test were used for statistical analyses. Results: Background suppression decreased signal variations for both NV and TK. Registration suppressed effects of kidney motion for NV, which was not critical for TK. The renal cortex showed greater perfusion than the renal medulla in both NV and TK(p < 0.01). TK showed greater renal perfusion than NV(p < 0.05). Cortical and medullary RBF values were 271.8 +/- 43.5, 119.1 +/- 15.1 ml/100 g/min for NV and 358.3 +/- 36.4, 141.0 +/- 11.5 ml/100 g/min for TK. TK showed longer ATT values than NV(p < 0.01). ATT values in the cortex and medulla were 641 +/- 141 and 746 +/- 150 ms for NV and 919 +/- 49 and 935 +/- 81 ms for TK. Conclusions: We demonstrated that although there is no discernible motion of the transplanted kidney, background suppression is necessary to suppress signal fluctuations in renal perfusion measurements. Also, relatively high RBF and long ATT values were observed in the transplanted kidneys in the early postoperative recovery phase, which requires further longitudinal studies.
Publisher
ELSEVIER IRELAND LTD
Issue Date
2020-09
Language
English
Article Type
Article
Citation

EUROPEAN JOURNAL OF RADIOLOGY, v.130, pp.109200

ISSN
0720-048X
DOI
10.1016/j.ejrad.2020.109200
URI
http://hdl.handle.net/10203/276645
Appears in Collection
BiS-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 12 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0