실내 대기질 진단을 위한 금속산화물 기반 폼알데하이드 가스센서 연구 동향Review of Metal Oxide-based Formaldehyde Gas Sensor to Measure Indoor Air Quality

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 387
  • Download : 0
DC FieldValueLanguage
dc.contributor.author김윤화ko
dc.contributor.author구원태ko
dc.contributor.author장지수ko
dc.contributor.author김일두ko
dc.date.accessioned2020-01-16T09:20:11Z-
dc.date.available2020-01-16T09:20:11Z-
dc.date.created2020-01-15-
dc.date.issued2019-11-
dc.identifier.citation센서학회지, v.28, no.6, pp.377 - 384-
dc.identifier.issn1225-5475-
dc.identifier.urihttp://hdl.handle.net/10203/271349-
dc.description.abstractPeople currently spend more than 80% of their time indoors; therefore, the management of indoor air quality has become an important issue. The contamination of indoor air can cause sick house syndrome and various environmental diseases such as atopy and nephropathy. Formaldehyde gas, which is the main contaminant of indoor air, is lethal even with microscopic exposure; however, it is commonly used as an adhesive and waterproofing agent for indoor building materials. Therefore, there is a need for a gas sensor capable of detecting trace amounts of formaldehyde gas. In this review, we summarize recent studies on metal oxide-based semiconductor gas sensors for formaldehyde gas detection, methods to improve the gas-sensing properties of metal oxides of various dimensions, and the effects of catalysts for the detection of parts-per-billion level gases. Through this, we discuss the necessary characteristics of the metal oxidebased semiconductors for gas sensors for the development of next-generation sensors.-
dc.languageKorean-
dc.publisher한국센서학회-
dc.title실내 대기질 진단을 위한 금속산화물 기반 폼알데하이드 가스센서 연구 동향-
dc.title.alternativeReview of Metal Oxide-based Formaldehyde Gas Sensor to Measure Indoor Air Quality-
dc.typeArticle-
dc.type.rimsART-
dc.citation.volume28-
dc.citation.issue6-
dc.citation.beginningpage377-
dc.citation.endingpage384-
dc.citation.publicationname센서학회지-
dc.identifier.doi10.5369/JSST.2019.28.6.377-
dc.identifier.kciidART002529130-
dc.contributor.localauthor김일두-
dc.contributor.nonIdAuthor김윤화-
dc.description.isOpenAccessN-
dc.subject.keywordAuthorGas sensors-
dc.subject.keywordAuthorFormaldehyde gas-
dc.subject.keywordAuthorSick house syndrome-
dc.subject.keywordAuthorIndoor air quality-
dc.subject.keywordAuthorMetal oxide-
Appears in Collection
MS-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0