Development of a bio-fluidic device for optical measurement and sample pretreatment광학측정 및 시료 전처리용 바이오유체소자의 개발

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 497
  • Download : 0
In recent years, many attempts have been made to miniaturize complex biochemical analytical process in lab-on-a-chip. Both limit in analytical range and poor accuracy of data have originated from the requirements of each reaction and measurement step. For example, samples with high concentration have been difficulty in measuring the actual concentration because of the narrow measurable range of an analytical instrument. In case of spectrophotometers, they should be used in the region of absorbance 0.4~0.7, because the high absorbance value exceeds the upper boundary of the measurable range. This thesis has intended to develop a bio-fluidic device, which enable adaptive pretreatment of sample to fulfill an optimal condition of analysis. Using bio-fluidic technique, it would take an advantage that instrument itself responds spontaneously to change the sample with broad range of conditions. Like the automatic gain control of electrical devices, suitable fluidic actuation in sample pretreatment would make improvements, such as expanded domain of acquirable signal and enhanced precision. In this study, we have developed a bio-fluidic device for optical measurement and sample pretreatment, by an automatic dilution, or a typical pretreatment, which has been required for measurement. To embody automatic dilution, two idea was exploited; dilution with programmable ratio, and to-and-fro mixing. The bio-fluidic device was fabricated in replica molding using PDMS (polydimethylsiloxane). The experimental apparatus consisted of fluid actuating syringe pumps, spectrometer, and personal computer where a VC++ user control program run. To verify the automatic dilution by bio-fluidic device, red dye solution was used to demonstrate the to-and-fro mixing. In addition, the specific dilution process to reach the target concentration was accomplished. Full mixing required at least 15 times to-and-fros in case of the viscosity 2.095 cp. Finally, the bio-fluidic device was used to me...
Advisors
Park, Je-Kyunresearcher박제균researcher
Description
한국과학기술원 : 바이오시스템학과,
Publisher
한국과학기술원
Issue Date
2004
Identifier
240423/325007  / 020033646
Language
eng
Description

학위논문(석사) - 한국과학기술원 : 바이오시스템학과, 2004.8, [ x, 57 p. ]

Keywords

TO-AND-FRO MIXING; AUTOMATIC DILUTION; BIO-FLUIDIC DEVICE; LAB-ON-A-CHIP; DILUTION WITH PROGRAMMABLE RATIO; 희석비율 조절 광학적 검출법; 왔다갔다 혼합; 자동희석; 바이오유체소자; 랩온어칩

URI
http://hdl.handle.net/10203/27101
Link
http://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=240423&flag=dissertation
Appears in Collection
BiS-Theses_Master(석사논문)