Ground reaction force estimation using an insole-type pressure mat and joint kinematics during walking

Cited 60 time in webofscience Cited 56 time in scopus
  • Hit : 174
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorJung, Yihwanko
dc.contributor.authorJung, Moonkiko
dc.contributor.authorLee, Kunwooko
dc.contributor.authorKoo, Seungbumko
dc.date.accessioned2019-04-15T14:50:23Z-
dc.date.available2019-04-15T14:50:23Z-
dc.date.created2018-09-10-
dc.date.issued2014-08-
dc.identifier.citationJOURNAL OF BIOMECHANICS, v.47, no.11, pp.2693 - 2699-
dc.identifier.issn0021-9290-
dc.identifier.urihttp://hdl.handle.net/10203/254415-
dc.description.abstractKinetic analysis of walking requires joint kinematics and ground reaction force (GRF) measurement, which are typically obtained from a force plate. GRF is difficult to measure in certain cases such as slope walking, stair climbing, and track running. Nevertheless, estimating GRF continues to be of great interest for simulating human walking. The purpose of the study was to develop reaction force models placed on the sole of the foot to estimate full GRF when only joint kinematics are provided (Type-I), and to estimate ground contact shear forces when both joint kinematics and foot pressure are provided (Type-II and Type-II-val). The GRF estimation models were attached to a commercial full body skeletal model using the AnyBody Modeling System, which has an inverse dynamics-based optimization solver. The anterior-posterior shear force and medial-lateral shear force could be estimated with approximate accuracies of 6% BW and 2% BW in all three methods, respectively. Vertical force could be estimated in the Type-I model with an accuracy of 13.75% BW. The accuracy of the force estimation was the highest during the mid-single-stance period with an average RMS for errors of 3.10% BW, 1.48% BW, and 7.48% BW for anterior-posterior force, medial-lateral force, and vertical force, respectively. The proposed GRF estimation models could predict full and partial GRF with high accuracy. The design of the contact elements of the proposed model should make it applicable to various activities where installation of a force measurement system is difficult, including track running and treadmill walking. (C) 2014 Elsevier Ltd. All rights reserved.-
dc.languageEnglish-
dc.publisherELSEVIER SCI LTD-
dc.subjectMODEL-
dc.subjectGAIT-
dc.subjectKNEE-
dc.subjectOSTEOARTHRITIS-
dc.subjectSIMULATIONS-
dc.subjectSYSTEM-
dc.titleGround reaction force estimation using an insole-type pressure mat and joint kinematics during walking-
dc.typeArticle-
dc.identifier.wosid000341462900024-
dc.identifier.scopusid2-s2.0-84905286610-
dc.type.rimsART-
dc.citation.volume47-
dc.citation.issue11-
dc.citation.beginningpage2693-
dc.citation.endingpage2699-
dc.citation.publicationnameJOURNAL OF BIOMECHANICS-
dc.identifier.doi10.1016/j.jbiomech.2014.05.007-
dc.contributor.localauthorKoo, Seungbum-
dc.contributor.nonIdAuthorJung, Yihwan-
dc.contributor.nonIdAuthorJung, Moonki-
dc.contributor.nonIdAuthorLee, Kunwoo-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorGait-
dc.subject.keywordAuthorMusculoskeletal simulation-
dc.subject.keywordAuthorGround reaction force-
dc.subject.keywordAuthorVirtual force plate-
dc.subject.keywordPlusMODEL-
dc.subject.keywordPlusGAIT-
dc.subject.keywordPlusKNEE-
dc.subject.keywordPlusOSTEOARTHRITIS-
dc.subject.keywordPlusSIMULATIONS-
dc.subject.keywordPlusSYSTEM-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 60 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0