An additional tilted-scan-based CT metal-artifact-reduction method for radiation therapy planning

Cited 6 time in webofscience Cited 6 time in scopus
  • Hit : 412
  • Download : 264
DC FieldValueLanguage
dc.contributor.authorKim, Changhwanko
dc.contributor.authorPua, Rizzako
dc.contributor.authorLee, Chung-Hwanko
dc.contributor.authorChoi, Da-inko
dc.contributor.authorCho, Byungchulko
dc.contributor.authorLee, Sang-wookko
dc.contributor.authorCho, Seungryongko
dc.contributor.authorKwak, Jungwonko
dc.date.accessioned2019-03-19T01:27:11Z-
dc.date.available2019-03-19T01:27:11Z-
dc.date.created2019-03-04-
dc.date.created2019-03-04-
dc.date.created2019-03-04-
dc.date.issued2019-01-
dc.identifier.citationJOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, v.20, no.1, pp.237 - 249-
dc.identifier.issn1526-9914-
dc.identifier.urihttp://hdl.handle.net/10203/251651-
dc.description.abstractPurpose: As computed tomography (CT) imaging is the most commonly used modality for treatment planning in radiation therapy, metal artifacts in the planning CT images may complicate the target delineation and reduce the dose calculation accuracy. Although current CT scanners do provide certain correction steps, it is a common understanding that there is not a universal solution yet to the metal artifact reduction (MAR) in general. Particularly noting the importance of MAR for radiation treatment planning, we propose a novel MAR method in this work that recruits an additional tilted CT scan and synthesizes nearly metal-artifact-free CT images. Methods: The proposed method is based on the facts that the most pronounced metal artifacts in CT images show up along the x-ray beam direction traversing multiple metallic objects and that a tilted CT scan can provide complementary information free of such metal artifacts in the earlier scan. Although the tilted CT scan would contain its own metal artifacts in the images, the artifacts may manifest in a different fashion leaving a chance to concatenate the two CT images with the metal artifacts much suppressed. We developed an image processing technique that uses the structural similarity (SSIM) for suppressing the metal artifacts. On top of the additional scan, we proposed to use an existing MAR method for each scan if necessary to further suppress the metal artifacts. Results: The proposed method was validated by a simulation study using the pelvic region of an XCAT numerical phantom and also by an experimental study using the head part of the Rando phantom. The proposed method was found to effectively reduce the metal artifacts. Quantitative analyses revealed that the proposed method reduced the mean absolute percentages of the error by up to 86% and 89% in the simulation and experimental studies, respectively. Conclusions: It was confirmed that the proposed method, using complementary information acquired from an additional tilted CT scan, can provide nearly metal-artifact-free images for the treatment planning.-
dc.languageEnglish-
dc.publisherWILEY-
dc.titleAn additional tilted-scan-based CT metal-artifact-reduction method for radiation therapy planning-
dc.typeArticle-
dc.identifier.wosid000458666000029-
dc.identifier.scopusid2-s2.0-85060029938-
dc.type.rimsART-
dc.citation.volume20-
dc.citation.issue1-
dc.citation.beginningpage237-
dc.citation.endingpage249-
dc.citation.publicationnameJOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS-
dc.identifier.doi10.1002/acm2.12523-
dc.contributor.localauthorCho, Seungryong-
dc.contributor.nonIdAuthorLee, Chung-Hwan-
dc.contributor.nonIdAuthorCho, Byungchul-
dc.contributor.nonIdAuthorLee, Sang-wook-
dc.contributor.nonIdAuthorKwak, Jungwon-
dc.description.isOpenAccessY-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorCT-
dc.subject.keywordAuthormetal artifact reduction-
dc.subject.keywordAuthorradiotherapy-
dc.subject.keywordPlusRAY COMPUTED-TOMOGRAPHY-
dc.subject.keywordPlusHIP-PROSTHESIS-
dc.subject.keywordPlusSUPPRESSION-
dc.subject.keywordPlusRECONSTRUCTION-
dc.subject.keywordPlusALGORITHM-
dc.subject.keywordPlusIMPLANTS-
dc.subject.keywordPlusPROTON-
dc.subject.keywordPlusIMPACT-
dc.subject.keywordPlusIMAGES-
dc.subject.keywordPlusRANGE-
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 6 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0