근접장 기록 장치를 위한 트랙킹 구동기의 설계 및 실험The disign and performance test of tracking actuator for NFR system

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 316
  • Download : 2
DC FieldValueLanguage
dc.contributor.author김기현ko
dc.contributor.author이문구ko
dc.contributor.author권대갑ko
dc.date.accessioned2011-07-04T07:25:21Z-
dc.date.available2011-07-04T07:25:21Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2001-08-
dc.identifier.citation한국정밀공학회지, pp.174 - 181-
dc.identifier.issn1225-9071-
dc.identifier.urihttp://hdl.handle.net/10203/24396-
dc.description.abstractNowadays, the improvement and development of Multi-media and information & communication technology is rapidly processed. They need large data storage capacity. So that, many studies and researches in data storage have been carried out. According to them, the data storage capacity has been increased. But the limitation of storage capacity is happened for several problems. One of them is spot & pit size in optical and magnetic data storage and another is the resolution of actuators. The problems in spot & pit size are covered by new data storage methods-- for examples, AFM(Atomic Force Microscopy), MO(Magneto-optical) system, and NFR(Near-Field decoding) system etc. But the resolution limit of an actuator was not developed and doesn\`t follow up the development of spot & pit size. Because of them, we should improve a resolution of an actuator. Especially, in this paper an actuator if studied and designed for NFR (in using SIL(Solid Immersion Lens) system. It is a dual stage actuator, which consists of a Fine actuator and a Coarse actuator. and should desire 100nm accuracy. Its actuating force generation method is VCM(Voice Coil Motor). The Fine actuator is composed of 4-leaf springs and a bobbin wrapped by coil. The Coarse actuator has Coils and 3-Roller bearings. Also, The Characteristics of designed actuator for NFR system is estimated by Sine-Swept mode and LDV(Laser Doppler Vibro-meter).-
dc.description.sponsorship본 연구는 한국과학재단 지정 정보 저장 기기 연구센터와 LG의 지원으로 이루어짐과 또한, VCM 제작에 도움을 주신 성림첨단산업과 한국오토피아에 감사 드립니다.en
dc.languageKorean-
dc.language.isokoen
dc.publisher한국정밀공학회-
dc.title근접장 기록 장치를 위한 트랙킹 구동기의 설계 및 실험-
dc.title.alternativeThe disign and performance test of tracking actuator for NFR system-
dc.typeArticle-
dc.subject.alternativeTracking Actuatoren
dc.subject.alternativePick-upen
dc.subject.alternativeDual Stageen
dc.subject.alternativeLeaf Springen
dc.subject.alternativeVCMen
dc.subject.alternativeFine Actuatoren
dc.subject.alternativeCoarse Actuatoren
dc.subject.alternativeNFRen
dc.type.rimsART-
dc.citation.beginningpage174-
dc.citation.endingpage181-
dc.citation.publicationname한국정밀공학회지-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.contributor.localauthor권대갑-
dc.contributor.nonIdAuthor김기현-
dc.contributor.nonIdAuthor이문구-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item

qr_code

  • mendeley