(The) Optical Low Angle Pass Filter for High Signal-to-noise Ratio Photoplethysmography Monitoring높은 신호 대 잡음비를 갖는 광용적맥파를 위한 저각도 광학 투과 필터

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 539
  • Download : 0
DC FieldValueLanguage
dc.contributor.advisorJeong, Ki-Hun-
dc.contributor.advisor정기훈-
dc.contributor.authorHwang, Chan-Sol-
dc.date.accessioned2018-06-20T06:17:20Z-
dc.date.available2018-06-20T06:17:20Z-
dc.date.issued2017-
dc.identifier.urihttp://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=675205&flag=dissertationen_US
dc.identifier.urihttp://hdl.handle.net/10203/242989-
dc.description학위논문(석사) - 한국과학기술원 : 바이오및뇌공학과, 2017.2,[vii, 51 p. :]-
dc.description.abstractThe photoplethysmography (PPG) signal exhibits the human vascular activity using the parameters extracted from the PPG waveform. However, the reflectance type PPG signal is liable to be distorted by noise. In this work, we present the optical low angle pass filter (OLAPF) for high signal-to-noise ratio photoplethysmography (PPG) monitoring. The highly scattered light, which loses their directionality under the human tissue act as a noise in PPG signal. The OLAPF can cut-off these scattered light using their non-directionality. The OLAPF was designed by the ray-optics analysis and numerical analysis. The fabrication of the OLAPF was done by using guided resist reflow and soft lithography method. To figure out the difference between with and without OLAPF, we made the conventional PPG sensor, which can be changed the glass on the photodetector to the OLAPF. As a result, the in-band noise overlapped the signal bandwidth of 0.5 Hz to 4 Hz with OLAPF is 2 times smaller than without the OLAPF. The low-frequency power spectral density, which has bandwidth of 0 Hz to 0.4 Hz of PPG signal with OLAPF is 3 times smaller than without OLAPF. This device can be applied not only PPG signal but also NIRS to improve the signal resolution.-
dc.languageeng-
dc.publisher한국과학기술원-
dc.subjectPhotoplethysmography-
dc.subjectOptical Filter-
dc.subjectLithography-
dc.subjectVascular Activity-
dc.subjectSignal-to-noise Ratio-
dc.subject광용적맥파-
dc.subject광학필터-
dc.subject리소그래피-
dc.subject혈관활동-
dc.subject신호 대 잡음비-
dc.title(The) Optical Low Angle Pass Filter for High Signal-to-noise Ratio Photoplethysmography Monitoring-
dc.title.alternative높은 신호 대 잡음비를 갖는 광용적맥파를 위한 저각도 광학 투과 필터-
dc.typeThesis(Master)-
dc.identifier.CNRN325007-
dc.description.department한국과학기술원 :바이오및뇌공학과,-
dc.contributor.alternativeauthor황찬솔-
Appears in Collection
BiS-Theses_Master(석사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0