DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yun, Jin Yeong | ko |
dc.contributor.author | Jo, Tae Geun | ko |
dc.contributor.author | Han, Jiyeon | ko |
dc.contributor.author | Jang, Hyo Jung | ko |
dc.contributor.author | Lim, Mi Hee | ko |
dc.contributor.author | Kim, Cheal | ko |
dc.date.accessioned | 2018-02-21T06:02:36Z | - |
dc.date.available | 2018-02-21T06:02:36Z | - |
dc.date.created | 2018-02-08 | - |
dc.date.created | 2018-02-08 | - |
dc.date.issued | 2018-02 | - |
dc.identifier.citation | SENSORS AND ACTUATORS B-CHEMICAL, v.255, pp.3108 - 3116 | - |
dc.identifier.issn | 0925-4005 | - |
dc.identifier.uri | http://hdl.handle.net/10203/240202 | - |
dc.description.abstract | A new highly selective chemosensor 1 (E)-5-((2-hydroxybenzylidene)amino)-1H-imidazole-4-carboxamide was designed and synthesized for the sequential recognition of Zn2+ and S2- in a near-perfect aqueous media. The sensor 1 exhibited a green color fluorescence in the presence of Zn2+. The detection limit (1.18 mu M) of 1 for Zn2+ is much lower than World Health Organization guideline (76 mu M) in drinking water. 1 can detect and quantify Zn2+ in real water samples and the sensing mechanism of Zn2+ by 1 was explained by DFT calculations. Moreover, resulting 1-Zn2+ complex can detect hydrogen sulfide through turn-off fluorescent change, without any anion interference. The detection limit (2.60 mu M) of 1-Zn2+ complex for S2- was much lower than EPA guideline (7.8 mM) by odor in drinking water. Furthermore, sensor 1 could detect sequentially Zn2+ and S2- in living cells. (C) 2017 Elsevier B.V. All rights reserved. | - |
dc.language | English | - |
dc.publisher | ELSEVIER SCIENCE SA | - |
dc.subject | IMAGING HYDROGEN-SULFIDE | - |
dc.subject | RELAY RECOGNITION | - |
dc.subject | SCHIFF-BASE | - |
dc.subject | LIVE CELLS | - |
dc.subject | IN-VITRO | - |
dc.subject | PROBE | - |
dc.subject | SENSOR | - |
dc.subject | FLUOROPHORE | - |
dc.subject | INDICATOR | - |
dc.subject | ENERGIES | - |
dc.title | A highly sensitive and selective fluorescent chemosensor for the sequential recognition of Zn2+ and S2- in living cells and aqueous media | - |
dc.type | Article | - |
dc.identifier.wosid | 000414686500082 | - |
dc.identifier.scopusid | 2-s2.0-85030466419 | - |
dc.type.rims | ART | - |
dc.citation.volume | 255 | - |
dc.citation.beginningpage | 3108 | - |
dc.citation.endingpage | 3116 | - |
dc.citation.publicationname | SENSORS AND ACTUATORS B-CHEMICAL | - |
dc.identifier.doi | 10.1016/j.snb.2017.09.136 | - |
dc.contributor.localauthor | Lim, Mi Hee | - |
dc.contributor.nonIdAuthor | Yun, Jin Yeong | - |
dc.contributor.nonIdAuthor | Jo, Tae Geun | - |
dc.contributor.nonIdAuthor | Han, Jiyeon | - |
dc.contributor.nonIdAuthor | Jang, Hyo Jung | - |
dc.contributor.nonIdAuthor | Kim, Cheal | - |
dc.description.isOpenAccess | N | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordAuthor | Zinc | - |
dc.subject.keywordAuthor | Sulfide | - |
dc.subject.keywordAuthor | Sequential detection | - |
dc.subject.keywordAuthor | Cell imaging | - |
dc.subject.keywordAuthor | Fluorescence | - |
dc.subject.keywordAuthor | Theoretical calculations | - |
dc.subject.keywordPlus | IMAGING HYDROGEN-SULFIDE | - |
dc.subject.keywordPlus | RELAY RECOGNITION | - |
dc.subject.keywordPlus | SCHIFF-BASE | - |
dc.subject.keywordPlus | LIVE CELLS | - |
dc.subject.keywordPlus | IN-VITRO | - |
dc.subject.keywordPlus | PROBE | - |
dc.subject.keywordPlus | SENSOR | - |
dc.subject.keywordPlus | FLUOROPHORE | - |
dc.subject.keywordPlus | INDICATOR | - |
dc.subject.keywordPlus | ENERGIES | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.